Safety
MiR100™ User Guide, Robot Interface 2.0, 08/2018 v.1.1
8
2.5 Safety circuit
If a person or other moving object enters the safety zones of the robot where the planner due to
response time, errors etc. does not respond, the safety circuit will force the robot into emergency
stop, and the robot stops immediately. When the person or object is out of the safety zone again,
the robot will automatically reset the emergency stop.
MiR100™ is designed with total redundant electrical safety circuit including Sick Safety components.
If any internal errors in the safety circuit occur, the robot will immediately go into emergency stop
which means that all moving parts will be voltage free by mechanical disconnection. Only when the
redundancy is provided, it is possible to reset the emergency stop and continue.