background image

© MOBATIME 

16/40 

BE-801259.05-HN 60&61master clock 

3.4  STRIKING screen  

Striking can only be set for clocks with the HN..SSR2 add-on module for classic bells or 
dulcimers; or on a clock with audio output for Audio striking. Only one type of striking can be 
activated. This is displayed when push gradually the      button from the MASTER screen. 

3.4.1  Striking bells or dulcimers 

Functional only if striking is activated in the menu. Displays the time period when striking is off, 
the type of striking and that is currently being striking. 

 

 

Button function: 

 

 

 

 

entry to striking set up menu (setting is described in chap. 10) 

long press  

 

block / unblock striking function 

3.4.2  Audio striking 

Functional only if striking is activated in the menu. Displays the time period when striking is off, 
the type of striking. 

 

Button function 

 

 

 

 

entry to striking set up menu (setting is described in chap. 10) 

long press 

 

block / unblock striking function 

 

 

Summary of Contents for HN 60

Page 1: ...MOBATIME 1 40 BE 801259 05 HN 60 61master clock USER MANUAL Mini Master clock HN 60 HN 61...

Page 2: ...connecting 10 2 6 1 Integrated GPS receiver 10 2 6 2 External GPS receiver 10 2 7 Switching channel 10 2 8 Connecting the striking module 11 2 9 Synchronization of slave clocks using DCF current loop...

Page 3: ...y 24 8 2 Switching illumination by calculated sunrise and sunset time 25 8 3 Switching MUTE signal 26 9 WEEK PROGRAM 27 9 1 View and edit program records for CH switch channel 27 9 2 View and edit AUD...

Page 4: ...MSF or GPS signal possibility of configuration for any time zone USB for connection of flash memory drive with saved switch programs powered by mains 115 or 230VAC or by DC power 12 or 24 VDC 1 1 2 Sw...

Page 5: ...ccelerated mode to the proper time the channel state corresponds to the actual time active internal circuit for charging the accumulators optional external maintenance free lead acid batteries energy...

Page 6: ...stallation procedure Snap the clock box onto the DIN rail Terminate all supply cables on the terminal box at the top of the clock box The wall mounting case has holes for supply cables in the top and...

Page 7: ...MOBATIME 7 40 BE 801259 05 HN 60 61master clock 2 3 2 DIN rail variant HN 60m 61m 2 3 3 DIN rail variant HN 60a 61a...

Page 8: ...g other external devices eg school bells can also be used as a 24 VDC power supply ACCU 14 V output for powering external devices or charging of external battery L1 slave line connection terminals DCF...

Page 9: ...Comprehensive information about time and date is then transmitted into the DCF transmitter located in Mainflingen near to Frankfurt The transmitter transmits long wave signals at 77 5 kHz frequency T...

Page 10: ...t eg GPS 4500 can be connected to the HN 61m as a source of synchronization signal eg if a sufficiently long extension of the coaxial cable of the magnetic GPS antenna is not available 2 7 Switching c...

Page 11: ...MOBATIME 11 40 BE 801259 05 HN 60 61master clock 2 8 Connecting the striking module Note Only for HN 60m 61m 2 9 Synchronization of slave clocks using DCF current loop...

Page 12: ...nformation manual time and date adjustment LINE information about the state of slave line time adjustment for the slave line CHANNEL information about the state of channel STRIKING status and striking...

Page 13: ...rating without a DCF or GPS receiver Button function move around the items change the blinking item automatic change when pressed down and held storage of values entered and return to the MASTER scree...

Page 14: ...catch up cycle overload line is overloaded or short circuit on line 12pos stop accelerated catch up cycle with automatic stop on 12 00 Note MOBALine time on the line is displayed only can t be set onl...

Page 15: ...n setting is described in chapter 9 long press lock unlock channel 3 3 2 Channel switches according to calculated of sunrise and sunset times Button function entry to coordinate settings and channel s...

Page 16: ...or dulcimers Functional only if striking is activated in the menu Displays the time period when striking is off the type of striking and that is currently being striking Button function entry to stri...

Page 17: ...CHRONIZATION QUALITY SCREEN It will be displayed when push gradually the button from the MASTER screen The value in indicates the reception quality of the last hour if the synchronization was successf...

Page 18: ...MOBATIME 18 40 BE 801259 05 HN 60 61master clock 3 6 VERSION screen This is displayed when push gradually the button from MASTER screen Button function entry into service menu only for service purpose...

Page 19: ...oad channel load pre prepared switching programs per USB into the main clock Button functions or change item confirm selection and enter settingsl return to the MASTER screen Main menu structure MASTE...

Page 20: ...return to the MAIN menu without saving Sync sources options DCF DCF receiver integrated input synchronization GPS integrated GPS receiver synchronization MSF MSF receiver DCF input synchronization WWV...

Page 21: ...Time zone table in chapter 12 In the MAIN Menu press the button to select Time Zones The menu contains two pages Button functions page switching enter the item settings on the current page return to M...

Page 22: ...MOBALine is set Button functions page switching enter the item settings on the current page return to MAIN menu Button functions in item edit mode moving between items change the blinking item while...

Page 23: ...owing line states run the line starts stop the line stops 12pos stop the line runs to 12 00 in accelerated mode and then stop If the MOBALine line type is set stopping the line will set the analog sla...

Page 24: ...tween items change the blinking item while holding auto load save the entered values and return to page view return without saving Note If channel is configured for manual switching at the same time i...

Page 25: ...witching off and switching off the channel Adjusting the value to the positive value speeds up the evening switching on and extends the switching off time in the morning Example no correction switch o...

Page 26: ...can only be used with a clock with audio output Use the button to select the mute position Selection of the channel CH1 CH1 CH2 for MHU 60a 61a only Note the channel cannot be selected if it is alread...

Page 27: ...channel If there are no records in the switching program Blank list is displayed Button functions move between records add new record delete of selected record edit of selected record return to channe...

Page 28: ...ngs Playback of audio file is available for HN 60a 61a only Playback is possible only from connected USB flash disk Button functions move between records add new record delete of selected record edit...

Page 29: ...k In computer prepare audio files in format wav with parameters audio channels 2 resolution 16bit sampling rate 48 000 Hz name of file number from 1 to 999 with suffix av e g 25 av Place this prepared...

Page 30: ...information screens Button functions switching pages enter the settings of the items on the current page return to the main menu Button functions in item editing mode move by items change the blinkin...

Page 31: ...it usually rings a quarter of an hour on a bell with a higher tone and full hours on a bell with a lower tone 10 2 Audio striking This function is used to set the parameters and type of Audio strikin...

Page 32: ...must be prepared for all day striking bell1h wav bell12h wav Place these prepared audio files in the root directory of the USB flash disk and connect the USB to the USB connector on the Master Clock...

Page 33: ...ash drive Insert USB flash drive into USB connector In MAIN Menu press the button to select Load channels The display shows the number of records that were found in the hn60 swprg file Press the butto...

Page 34: ...synthetic passive GPS input for external antenna USB mono audio output 3 5 jack 1 2 outputs GPIO 4 digital outputs OC open collector max 100 mA For HN 60m 61m output 12 and 24 VDC max 200 mA summary...

Page 35: ...at the VDC terminal 24 VDC 24 VDC 4 max possible current consumption from VDC terminal 200 mA 200 mA 2 impulse line voltage 12 24 V 12 24 V 12 24 V active operaration reserve Pb accumulator 5 fitted...

Page 36: ...r if the masterclock is powered by mains 230 VAC 115 VAC and equipped with an active battery backup 12 V accumulator connected to ACCU In case of no mains power is available and masterclock should be...

Page 37: ...3 59 Last Fri Oct 01 00 07 UTC GMT 0 No 08 Istanbul Kuwait City Minsk Moscow Saint Petersburg Volgograd 3 No 09 Praia Cape Verde 1 No 10 UTC GMT 0 No 11 Abu Dhabi Muscat Tbilisi Samara 4 No 12 Kabul 4...

Page 38: ...ico City Mexico 6 Yes 1st Sun Apr 02 00 Last Sun Oct 02 00 48 Adak Aleutian Is 10 Yes 2nd Sun Mar 02 00 1st Sun Nov 02 00 49 UTC GMT 0 No 50 UTC GMT 0 No 51 UTC GMT 0 No 52 UTC GMT 0 No 53 UTC GMT 0 N...

Page 39: ...to be located outside of working radius of high voltage power sources Also it can not be exposed to direct impact of solar radiation The device is covered with a 24 month warranty starting from the d...

Page 40: ...MOBATIME 40 40 BE 801259 05 HN 60 61master clock...

Reviews: