Operating Instructions MG3 Digital
How to …?
76609409EN-BA-MG3D-V1_6.docx 64/82
2010-08-02
5.19
Having Limit Values Determined Statistically
Procedure
•
Select button HISTOGRAM with the
knob/pushbutton combination and depress
button.
•
Screen SPC-chart opens, and now you may
perform all necessary settings.
Note
Before accepting the limit values:
•
Limit monitoring for the respective quantity
must be enabled (i.e. the button for
monitoring must be “ON”). See section 5.8.
•
A large number of measurements must be
recorded with the statistical evaluation
enabled
The more measurements have been recorded
and the larger the number of samples, the
more precise the result of limit value
determination will be.
In the histogram you can see average and
standard deviation values calculated of all
measured values.
DEFINE LIMITS
Calculates new limit values and shows a
window which acknowledges that these have
been imported. The newly-calculated limit
values are activated if importing is
acknowledged.