Operating Instructions MG3 Digital
How to …?
76609409EN-BA-MG3D-V1_6.docx 54/82
2010-08-02
The double arrow pointing upwards is located
on the left-hand side and can be used to reach
the first level again in which you can allocate
the graph individual colors with the PEN
selection field.
PEN
The colors green, red, blue and brown can be
selected in the field next to PEN.
The selected pen color can be allocated a
physical dimension in the adjacent selection
field.
Enter a “ – “ here if you do not desire an
enlarged representation.
The last variable entered becomes the primary
measurement variable to which the Y-axis
scaling relates.
The primary variable can be recognized by the
fact that it is shown in the heading and
illustrated in blue in the legend.
Enlarging menu (Zoom)
YMAX / YMIN
Press YMAX or YMIN to determine the upper or
lower Y-axis scale value for the primary
measurement variable selected in the PEN
field.
XMAX / XMIN
Press XMAX or XMIN to determine the upper or
lower scale value of the X-axis for all illustrated
measurement variables.
Y<-> / X<->
A range can be determined with Y<-> and
X<-> which will subsequently be enlarged.
A white line appears if Y<-> or X<-> is
selected. Turn the knob/button to offset the
line. Press the button to set the limit.