Operating Instructions MG3 Digital
How to …?
76609409EN-BA-MG3D-V1_6.docx 52/82
2010-08-02
5.11
Counting Measurements
Notes
•
On this screen, you can determine the
welding numbering system for channel 1
and 2.
•
The signal at the digital output on the rear
of the device becomes available when the
set pre-warning value is reached.
•
The signal at the digital output on the rear
of the device becomes available when the
end value (numerical dir) or zero
(numerical direction -) is reached.
Procedure
•
Select button MENU with the
knob/pushbutton combination and depress
button.
•
Select button COUNTER with the
knob/pushbutton combination and depress
button.
•
Screen COUNTER opens, and now you may
perform all necessary settings.
ON/OFF
Enables/disables the counter for the respective
channel
MODE
Indicates counting direction.
Plus (+) counts forward
Minus (-) counts backward
END VALUE
Last counter value of plus counter
START VALUE
First counter value of minus counter
PREWARN
Pre-warning value of active counter
RESET
Depressing button RESET resets the counter.