Operating Instructions MG3 Digital
Commissioning
76609409EN-BA-MG3D-V1_6.docx 17/82
2010-08-02
3.1.2.4
Connector X38 (I/O Inputs)
Pin
Name
Function
22
Ground connection
Common connection of the inputs.
35
n/c
36
n/c
37
n/c
38
n/c
39
Reference run part
detection 1 and 2
if this input is active, the reference value is determined
on the next parts detection run without inserted
component
Adjustment: Path-measuring mode to reference
41
n/c
42
n/c
43
n/c
44
n/c
45
Null Sinking 2
Setting = Null Sinking 2 with rising slope, zeroing with
rising slope, cooling time with dropping slope.
46
Null Sinking 1
Setting = Null Sinking 1 with rising slope, zeroing with
rising slope, cooling time with dropping slope.
47
Parts Detection 2
Setting to parts detection = HWScan.
Measured value evaluated and part set to min. 2 – max.
2.
48
Parts Detection 1
Setting to parts detection = HWScan.
Measured value evaluated and part set to min. 1 – max.
1.
49
Start Measure 2
Part detection 2 for sensor 1 started.
50
Start Measure 1
Part detection 1 for sensor 1 started.
3.1.2.5
Connector X51 (RS232) / Baud rate
Pin
Name
1
free
2
TxD
3
RxD
4
5V
5
GND
6
free
7
CTS
8
RTS
9
free
Baud rates (bit/s)
9600; 19200; 38400; 57600; 115200
Data bits
8
Start bits
1
Stop bits
1
Parity
none
Busy Control
no/off