IPB-5000A
9. Time Chart
9-6
(5) Behavior of SOL1 and SOL2
SOL1
Output works by the Input of
1ST STAGE
. When
1ST STAGE
Input is open,
SOL1
Output also becomes open if it is before the start of a weld sequence. After
the start of a sequence, even if
1ST STAGE
Input is open,
SOL1
Output keeps
closed until the sequence comes to an end.
When using
SOL1
,
1ST STAGE
Input allows
SOL1
to adjust a squeeze location.
After inputting
1ST STAGE
, weld current can be supplied by
2ND STAGE
Input.
SOL1
becomes opened with
SOL2
output after the end of HO in spite of the input
condition of
1ST STAGE
.
SOL2
output works by the Input of
2ND STAGE
and is closed from SQ to HO.
Symbol:
SQ: Squeeze Time
RC: Resistance Pre-check Time
CP: Resistance Judgment Time (1ms) U1: Upslope 1 Time
W1: 1st Weld Time
D1: Downslope 1 Time
CO: Cool Time
U2: Upslope 2 Time
W2: 2nd Weld Time
D2: Downslope 2 Time
HO: Hold Time
a
: When
1ST STAGE
Input is open before the start of a weld sequence,
SOL1
Output also becomes open
b
: Once the sequence is started,
SOL1
Output keeps closed until HO is
completed even if
1ST STAGE
Input is made open.
c
:
START SIG. TIME
, the period set for prevention of chattering,
END Output
SOL2 Output
SOL1 Output
2ND STAGE
1ST STAGE
OFF
OFF
OFF
OFF
OFF
OFF
a
b
c
SQ
RC
CP
U1
W1
D1
CO
U2
W2
D2
HO
Weld Current
Summary of Contents for IPB-5000A