IPB-5000A
6. Discription of Display Screens
6-14
(8) CONTROL Screen
Depict the screens of setting Weld Stop Function, Weld Time Comparator, etc.
(
a
)
INPUT
Selects the type of Weld Stops.
OFF
: External Input,
WE1
Stop Input and Interrupt Input are effective.
DISPLC
: Weld Stop works at the set displacement value (only for Sensor
equipped).
CURR
: Weld Stop works at the set current value.
VOLT
: Weld Stop works at the set voltage value.
(
b
)
CONDITION
Input the value depending on the setting at
(
a
)
.
OFF
: Not displayed.
DISPLC
: Input the value of displacement.
CURR
: Input current value.
VOLT
: Input voltage value.
(
c
)
HI
Input the upper limit of Weld Time.
(
d
)
LOW
Input the lower limit of Weld Time.
(
e
)
COMP
Input the upper limit (
HI
)/ lower limit (
LOW
) of a final displacement.
(Works only for Model equipped with Displacement Sensor. When using the
function of Displacement Sensor, the displacement from Weld Start to the end
of
DELAY TIME
is measured to judge the upper and lower limit.)
(a)
(c)
(d)
(e)
(f)
(g)
(h)
(b)