IPB-5000A
9. Time Chart
9-9
(8) Behavior in TRANS SCAN MODE
①
OFF Setting
It is a setting of the case where Transformer Selector
MA-650A
is not used.
The behavior is the same as the one in
(1) Fundamental Sequence
.
Those settings mentioned below in
②
through
⑥
are the ones of the case
where Transformer Selector
MA-650A
is used.
②
ON Setting
The weld current is supplied through the transformer set at the item of
Transformer No. (
TR#
) in
SCHEDULE Screen
.
Supposing that
SCHEDULE No.
is 2 (
SCH2
) and Transformer No. is 3 (
TR#3
),
the time chart where the supply of weld current is started is shown as follows.
a: Transformer Changeover Time (10ms)
b: Time period for computing a monitored value
See
b: Time period for computing a monitored value
at
9.(1)Fundamental Sequence
.
Because Transformer 3 (
TR#3
) is set for
SCHEDULE#2
(
SCH2
), weld
current is supplied through the Transformer connected to Transformer 3 in
Transformer Selector
MA-650A
.
END Output
OFF
SOL2 Output
SOL1 Output
2ND STAGE
1ST STAGE
OFF
OFF
OFF
OFF
Transformer No.
ON Setting in Transformer Selector
Weld
SCH2
TR#3
a
b