6. Discription of Display Screens
6-15
(
f
)
DELAY TIME
Sets
Delay Time
, the time period from Weld Stop to the time when a final
displacement is measured (only for Sensor equipped). The setting range is
from 0 to the time period of
HOLD TIME
(
See (3)
①
(b)
).
(
g
)
WORK DETECT
Input the upper limit (
HI
)/ lower limit (
LOW
) value at the time of detecting work
piece (only for Sensor equipped).
No detection of work piece is done in the case that “0” is set to both the upper
limit and lower limit.
For the detection of work piece, the position of Sensor where the work piece is
set between electrodes is taken as the base point. The larger displacement
without work piece than the displacement with work piece is detected to judge
whether or not the work piece is set.
(
h
)
MONITOR
Displays the displacement at the time of detecting work piece, the time of the
end of squeeze time (only for Sensor equipped).