![Mitutoyo 542-071 User'S Manual / Instructions For Use Download Page 53](http://html1.mh-extra.com/html/mitutoyo/542-071/542-071_users-manual-instructions-for-use_1812319053.webp)
5 External Input/Output Function
39
No. 99MBC109B
z
Example of external output of parameters
An example of the output of parameters is shown below.
Tips
The set values for the parameters in the table below are set by the user.
CQ01,**EH-S [200]**:00
CQ01,P02___=[0],0-1:02
CQ01,P05___=[0],0-1:03
CQ01,P10_A_=[0],0-1:36
CQ01,P10_B_=[0],0-1:37
CQ01,P40_1_=[0],0-4:42
CQ02,P40_2_=[0],0-4:43
CQ03,P40_3_=[0],0-4:44
CQ04,P40_4_=[0],0-4:45
CQ01,*parameter END*:FF
CQ01,P02___=[0],0-1:02
Per-axis
parameter example
Per-CEL
parameter example
Parameters
No.
Parameters
set value
Parameter set
value range
Internal data
Loading parameters
This section explains how to read parameters.
1
Press and hold [P.SET], and then press [A_ZERO]/[ZERO].
» The Counter enters Parameter mode.
2
Press [A_ZERO]/[ZERO] 4 times to set the parameter number 00 to 4.
3
Press [P.SET].
» The display appears as to the right.
4
Send the parameter file from the PC.
» If it is successfully received, the
display to the right will appear.
5
Press [P.SET].
» The Counter will return to the stand-by state.
Tips
After loading the parameters, turn off the power switch once, and then turn it on again.
Summary of Contents for 542-071
Page 14: ...xii No 99MBC034B...
Page 20: ...1 Overview 6 No 99MBC109B MEMO...