5-7
DC Supply Source Locations
The DC supplies shown in
Figures 5-1 and 5-3
are
located on the PCB-POWER. Additional supplies
are generated from these supplies on other PCBs. In
the Service Manual DC Supplies are designated with
a "V" or "VS".
• "V" designates a Switched Supply (5V)
• "VS" designates a Standby Supply (5VS)
All current rated in mA.
Name
9VS
2
12V
1
12V
2
12VS 17V
-24V
24V 28VS 32VS 110V 220V Heater
Voltage
9
12
12
12
17
-24
24
28
32
110
220
6.3
3DYC
Ant.
Relay
200
Audio
Amp
2250
Audio
Process
AV
Switch
Conv.
Gen
Conv.
Out
700
700
CRT
(video)
150
50
DBF
1
4
Digital
Module
310
CRT
630
HV
17
400
H-Defl
6
500
Jungle
TV µPC
V-Chip
(Sub)
Misc
(main)
70
Preamp
Protect
1
AMDP
Sub
Decoder
SVM
6
30
Switch
(signal)
Tuner
(DM)
1
Tuner
(signal)
4
V-Defl.
300
2H
Enhance
Video
Chroma
Table 5-2: Power Distribution Estimate (9VS to 220V Supplies)
Table 5-1
shows the Power Distribution for the 3.3V
through 9V supplies, and
Table 5-2
for the 9VS to
220V supplies. The tables indicate the estimated
current, in Ma, supplied to the various circuits. When
there is more than one supply of the same value, a
superscript number is added to those supplies. For
instance, 3.3V
1
and 3.3V
2
are different supplies.
Summary of Contents for V19-V21
Page 2: ......
Page 12: ...1 8...
Page 14: ...2 2...
Page 17: ...3 3...
Page 22: ...4 4 Adjustments RefertotheServiceManualforspecificadjustmentpro cedures...
Page 41: ...6 11 Figure 6 11 E2P Module Plugged In Figure 6 12 E2P Module Unplugged E2P MODULE...
Page 42: ...6 12...
Page 60: ...8 8...
Page 62: ...9 2...
Page 64: ...9 4...