150
-
'11 • SCM-SM-110
Color
Mark
BK
Color Marks
Black
BL
Blue
BR
Brown
Color
Mark
RD
Red
WH
White
RD
CNW0
BL
WH
RD
X1
3
UH
BR
WH
CNM3
C
WH
1
F
㧔
3.15A
㧕
1
3
X6
M
H
BK
BL
5
7
L
RD
9
X3
X2
5
BK
BK
CNB WH
1
3
1
3
TB1
220
㨺
240V
LED
2
SW2
SW6
SW5
SW7
LED
3
F
㧔
3.15A
㧕
Y
㧛
GN
TB2
X Y
WH
BK
Trl
RD RD BR BR
BK
CNW2
19V
24V
1 2 3 4 5
CNJ WH
BL
P
BR
OR
RD
M
LM
WH
CNF1
CNR
3
1
WH
X4
CNI
BL
WH
CNW1
M
1
XR1
XR2
XR3
XR4
Option
1
2
3
4
5
6
+12
CNT
BL
Control PCB
5
LED4
SW1
LED2 LED3
AMP
SW4
CNB2
WH
CNB
1
2
3
4
CNN Y
5
6
1
2
BK
CNH
Th -R1
Th -A
Th -R2
t
t
Th -R3
t
t
I
I
I
I
BK
BK
BK
BK
WH
RD
Receiver PCB
Receiver PCB
Capacitor for FMI
CFI 1
FMI 1
Transformer
Trl
SW2
Connector
CNB
ޓ
Z
TB1
Relay for FM
X1
ޓ
3,6
SW5
Operation check, Drain motor test run
SW7-1
Fuse
F
Thl -R1,2,3
Thl -A
Thc
LED
3
LED
2
Relay for DM
X4
TB2
Fan motor
㧔
with thermostat
㧕
Indication lamp
㧔
Green-Normal operation
㧕
Indication lamp
㧔
Red-Inspection
㧕
Remote controller communication address
Plural units Master
㧛
Slave setting
Terminal block
ާ
Power source
㧕㧔غ
mark
㧕
Terminal block
ާ
Signal line
㧕㧔غ
mark
㧕
Thermistor
ާ
Remote controller
㧕
Thermistor
ާ
Return air
㧕
Thermistor
ާ
Heat exchanger
㧕
LM
Louver motor
SW6
Model capacity setting
7-segment display
Switches for setting
SW1
LED2
Back-up switch
㧔
Operation
㧛
Stop
㧕
SW4
Indication lamp
㧔
Green-Normal operation
㧕
LED3
Indication lamp
㧔
Yellow-Timer
㧛
Inspection
㧕
LED4
BK
BK
BK
BK
XR5
㧔
Remote operation input :
㧔
Operation
㧕
㧔
Heating
㧕
㧔
Compressor ON
㧕
㧔
Inspection
㧕
volt-free contact
㧕
Remote
controller
C
2
Earth
Power source line
Signal line
1 2
3
indoor unit and outdoor unit
Connecting line between
P
Pink
OR
Orange
Remote
Thc
TB2
Wired specification
Wireless specification
X
Y
X
Y
t
controller
WH
Y
㧛
GN Yellow
㧛
Green
Y
Yellow
CF
I
1
FMI 1
CNFI 1
WH
Notes 1. indicates wiring on site.
ޓޓ
2. See the wiring diagram of outside unit about the line between
indoor unit and outdoor unit.
Y
㧛
GN
ޓޓ
4. Do not put remote controller line alongside power source line.
OR
OR
̪
When wired remote controller are used
only
㧔
wireless type
㧕
It is necessary to remove the line that is
connected to the receiver.
Remove signal line connected to the receiver
from primary side of terminal block
㧔
X,Y
㧕
.
ATTENTION
ޓ
Insulate with tape the removed line.
The LED of that removed connector will
not be able to make any indication.
Ԙ
ԙ
)'06+6.'..
)'06+6.'+05'46
)'06+6.'47
)'06+6.'/#:
ޓ
3. Use twin core cable
㧔
0.3mm
㧕
at remote controller line.
㧔
Refer to page 30
㧕
ޓ
of remote controller in case that the total length is more than 100m.
2
(5) Ceiling suspended type (FDEN)
Model FDEN50VD
A
P
F
A
0
0
3
Z
8
1
9