68
1101
The sequence program storing built-in
RAM/program memory in the CPU
module is faulty.
• Take noise reduction measures.
• Reset the CPU module and RUN it
again. If the same error is displayed
again,this suggests a CPU module
hardware fault.(Contact your local
Mitsubishi representative.)
QnA
1102
The work area RAM in the CPU module
is faulty.
• Take noise reduction measures.
• Reset the CPU module and RUN it
again. If the same error is displayed
again,this suggests a CPU module
hardware fault.(Contact your local
Mitsubishi representative.)
QnA
1103
The device memory in the CPU module
is faulty.
• Take noise reduction measures.
• When indexing is performed, check
the value of index register to see if it
is within the device range.
• Reset the CPU module and RUN it
again. If the same error is displayed
again,this suggests a CPU module
hardware fault.(Contact your local
Mitsubishi representative.)
QnA
1104
The address RAM in the CPU module is
faulty.
• Take noise reduction measures.
• Reset the CPU module and RUN it
again.If the same error is displayed
again, this suggests a CPU module
hardware fault. (Contact your local
Mitsubishi representative.)
QnA
1105
The system RAM in the CPU module is
faulty.
Q4AR
Error
Code
(SD0)
Error Contents and Cause
Corrective Action
Corresponding
CPU