31
1. Remove the filter and the water tank
2. Detach the rear panel
3. Detach the front panel assembly
<<Demounting the control board>>
(See Pictures 1 and 2.)
Picture 2
Picture 6
Rear panel
Filter
Rear panel setscrews
(3 on each side)
(See Picture 5.)
Repairable
parts
Board cover setscrews (2)
Picture 1
Water tank
Front panel setscrews
(2 on each side of the front)
Picture 4
Detach 2 connectors with
leads
Picture 5
Tube temperature
sensor
Solenoid valve
Picture 3
Front panel assembly
Thermal relay
Front panel setscrew
(one on each side of the rear)
Control board setscrews (2)
(Enlarged view)
Wrap the
cushion on the
leadwires and
insert halfway
into the hole.
Step 1) Detach the rear panel as directed in
Procedures 1 and 2 above.
2) Remove the front panel setscrews (2 on each
side of the front).
(See Picture 3.)
3) Remove the front panel setscrews (1 each on
the left and right) from the rear.
(See Picture 3.)
4) Slide the front panel upward, then forward
(straight) to avoid the swing louvre.
5) Pull the front panel forward and remove it by
releasing the main board connectors (P100,
P101) and leadwire set tape from the power
supply board.
Step 1) Remove the rear panel setscrews (6).
(See Picture 2.)
2) Pull out the rear panel.
(See Picture 3.)
Control board, power supply board,
solenoid valve, tube temperature sensor,
room temperature and humidity sensor,
stepping motor
Step 1) Remove 2 board cover setscrews.
(See Picture 6.)
2) Remove the panel cover from the front panel.
3) Remove the 2 control board set screws.
4) Life off the control board.
9. Disassembly and Reassembly Hints
9.1 Disassembly procedure