8.2 Key Component Check Procedures
Component name
Testing procedure
Tub temperature
sensing thermistor
Room
temperature and
humidity sensor
board
Compressor
Fan motor
Solenoid valve
coil
Detach the connector and measure the resistance using a multimeter
(component temperature: 10
°
C to 30
°
C).
Detach the connector and measure the resistance using a multimeter
(component temperature: 10
°
C to 30
°
C).
With the connector detached, measure the resistance across the terminals using a multimeter
(winding temperature: 10
°
C to 30
°
C).
Normal
Abnormal
Between P11 pins: 8.0k
Ω
to 20.8k
Ω
Normal: 47 to 51k
Ω
(between P10 pins 3 and 4)
Abnormal: Open or shorted
P11
Open or shorted
Normal
Abnormal
Open or shorted
Measure the resistance between terminals using a multimeter
(component temperature: 10
°
C to 30
°
C).
Measure the resistance between terminals using a multimeter
(winding temperature: 10
°
C to 30
°
C).
2.6k
Ω
~ 2.9k
Ω
Open or shorted
Normal
Abnormal
25.0
Ω
~ 27.1
Ω
67.9
Ω
~ 73.5
Ω
C-R side
C-S side
Open or shorted
Normal
Abnormal
258
Ω
~ 280
Ω
379
Ω
~ 411
Ω
Yellow-Blue
Black-Blue
Stepping motor
Measure the resistance across terminals with a multimeter.
(Part temperature: approx 25
°
C)
Open or shorted
Normal
Abnormal
342
Ω
~ 418
Ω
Terminals 1-2
Terminals 1-3
Terminals 1-4