300
-
<
SUB PCB:PCB2
>
Connector
Connected to
Normal value
Remark
R
IN
TB1(L)
AC220-240V
Power source
S
IN
TB1(N)
AC0V
Power source
RO
R-1 of Main PCB
AC220-240V
SO
S-1 of Main PCB
AC0V
S-1 - C-1
S-2,C-2 of Main PCB
DC20V
CN20V
CNSUB of Main PCB
DC20V
CNA(Black-White)
Indoor unit A
AC220-240V
Power source
CNA(Red)
Indoor unit A
AC0V
Earth
CNB(Black-White)
Indoor unit B
AC220-240V
Power source
CNB(Brown)
Indoor unit B
AC0V
Earth
CNC(Black-White)
Indoor unit C
AC220-240V
Power source
CNC(Blue)
Indoor unit C
AC0V
Earth
CND(Black-White)
Indoor unit D
AC220-240V
Power source
CND(Yellow)
Indoor unit D
AC0V
Earth
CNEEV1
EEV A(WH) and EEV B(RD)
CNMAIN(1-4)
DC13V
CNMAIN(5-4)
DC5V
CNEEV2
EEV C(BL) and EEV D(GN)
CNSUB of Main PCB
Black cable
White cable
to N-terminal
CN20V
CNEEV2
CNMAIN
CNEEV1
RO (BK)
SO (WH)
C-1 (RD)
S-1 (WH)
CNA
CNB
CNC
CND
Grounding cables
'17 • SCM-T-225