9. TABLE OF FUNCTIONS CONNECTED WIRED REMOTE CONTROL (RC-E5)
NO.
Functions
SRK SRR SRF
Outline of function
Remarks
1 Several remote controls for 1unit
○
○
○
Indoor unit can be connected max. 2 remote controls.
2 Control of several indoor units
○
○
○
One remote control can be connected toa max. of 16
indoor unit.
3 Plural control
△
×
×
One outdoor unit can be connected to a max. of 4 indoor
units.
Only SRK50,60ZSX-S
4 Central control
○
○
○
Signal of center mode from central control can be
restricted to operation of remote control.
5 Run/Stop
○
○
○
6 Change operation mode
○
○
○
Display of operation mode range is automatically decided
from the indoor unit's imformation.
7 Adjust fan speed
○
○
○
Display of airflow range is automatically decided from the
indoor unit's imformation.
8 Auto swing of flap
○
×
○
Display of air flow direction ON/OFF is automatically
decided from the indoor unit's imformation.
Flap control only. Louver cannot be controlled.
9 Setting of air flow direction
×
×
×
Setting of air flow direction for indoor unit that can be
changed air flow direction.
10 Setting of temperture
△
△
△
Temperture range can be set from 18 degree to
30 degree. Carving 0.5
℃
is rounded up.
11 Timer operation
○
○
○
Sleep timer mode, Off timer mode, On timer mode,
Weekly timer mode.
Warm up timer and sleep control of on timer
mode is impossible.
12
13
14
Ventilation control
×
×
×
Air infiltration can be controlled by the indoor unit that
has this function.
RAC unit does not have this function.
15
Display of unit number
○
○
○
Display address number of remote control.
Address setted by SC-BIKN2-E for RAC
16
Service switch-1: Display of error
data
△
△
△
Display and memorize the error code data that are checked
finally.
Only error code is used in the RAC unit.
17
Service switch -2 display of
operation data
△
△
△
Display operation data.
RAC unit can be displayed some data.
18
Trial run
○
○
○
Cooling operation signal is sent to the indoor unit.
19
Forced operation of drain pump
×
×
Forced operation of drain pump is sent to the indoor unit.
20
Setting of compressor frequency
○
○
○
Fixing compressor frequency.
21
Quiet mode
×
×
×
On timer in order to start quiet mode.
RAC unit does not have this function.
22
Auto address change from remote
control
×
×
×
Auto address can be changed from remote control.
RAC unit does not have this function.
23
Indoor unit's address set of master
×
×
×
Adapt control for 3 pipe system.
RAC unit does not have this function.
24
Filter reset
×
×
×
Turning off signal display of filter sign and sending reset
signal of operating time.
RAC unit does not have this function.
25
Clear memory of error code in
remote control
○
○
○
Reset memory that remote control has the error code.
26
Clear memory of error code in the
indoor unit
○
○
○
Reset memory of error for the indoor unit.
27
Clear address in indoor unit
×
×
×
Reset memory of address for the indoor unit.
RAC unit does not have this function.
28
Reset CPU
○
○
○
Reset outdoor or indoor CPU.
29
Function setting
△
△
△
It is possible to set the function of remote control and
indoor unit.
RAC unit can be set a part of function.
30
Setting of temperature range
△
△
△
Set Max and Min temperature.
For RAC models, only the range from 18
℃
to
30
℃
is available.
31
External input
○
○
○
External input from CnT terminal can be switched
between all unit operation and individual operation.
32
Auto adjustment of static pressure
×
×
×
Change auto adjustment of static pressure.
RAC unit does not have this function.
Setting of static pressure
×
×
×
Displayed part blinks on and off when it recives a
signal about auto adjustment of static pressure mode.
RAC unit does not have this function.
Filter sign
×
×
×
Displays filter sign via signal from indoor unit when
counting time achieves target time.
RAC unit does not have this function.
○:
OK,
△:
Conditionally OK,
×:
N/A
If wired remote control (option part) is connected to the following indoor units, some of the functions cannot be used. Please
see following table for details.
・
Wall mounted type
:
SRK
**
ZSX-S, ZS-S
・
Floor standing type
:
SRF
**
ZMX-S, ZMA-S
・
Ceiling concealed type
:
SRR
**
ZM-S
×
'17 • SCM-T-225