EN-66
Automatic cleaning filter (continued)
How to clean the automatic cleaning filter
Check the amount of dust through the dust check
window of the ilter cover and clean it, if necessary.
Before cleaning the ilter, be sure to turn off the main
power switch of the projector and unplug the power
cord from the outlet.
• When the dust box of the automatic cleaning ilter
is illed up with dust, the cleaning ability decreases.
If you use the projector in such a state, the ilter is
covered by the dust and the temperature inside the
product abnormally rises, damaging the internal
parts and components and affecting the panel’s
lifetime, resulting in a breakdown.
•
When the temperature inside the projector is
abnormally high, the projector may automatically
turn off and go into the standby mode where the
light source lamps are off to protect the internal
parts and components.
1. Loosen the screw (a) that is securing the ilter cover
using a Philips screwdriver and remove the ilter
cover (b) from the projector.
(a)
Dust check window
(b)
2. Remove the automatic cleaning ilter.
3. Remove the dust box from the automatic cleaning
ilter and get rid of the dust from it.
• Suck dirt and dust from the automatic cleaning
ilter and projector using a vacuum cleaner.
4. Attach the dust box to the automatic cleaning ilter.
5. Attach the automatic cleaning ilter.
6. Insert the ilter cover (b) into the projector and
tighten the screw (a) on the ilter cover irmly using
a Philips screwdriver.
(b)