40
VS-60HS12U Set-up Manual
In
pu
t me
mo
ry
s
ett
in
g
ASPECT RATIO
INPUT MEMORY > DETAIL > ASPECT RATIO
Aspect ratios to display input signals can be defined
among AUTO, 4:3, 5:4 and 16:9. The AUTO setting
displays the images at the ratio which has been set in H.
SIZE, V. SIZE menus (page 39). The initial setting is
AUTO.
•
Even if the original input signal is 16:9, the image will
be processed as a 4:3 image when it is set 4:3 in this
menu.
SIGNAL TYPE
INPUT MEMORY > DETAIL > SIGNAL TYPE
Signal types can be selected among RGB, YPbPr and
YCbCr according to input signals.
INTERLACE
INPUT MEMORY > DETAIL > INTERLACE
Scan modes in interlace signals can be selected as
needed.
n
ADAPTIVE: for 1080i signals
n
STATIC: for static images in interlace signals
n
OFF: for non-interlace signals
FIELD JUDGEMENT
INPUT MEMORY > DETAIL > FIELD JUDGEMENT
Even / odd fields in interlace signals can be reversed
when hatched lines on an image are jagged.
•
It is available when the INTERLACE menu is set
STATIC or ADAPTIVE.
SCALING FILTER
INPUT MEMORY > DETAIL > SCALING FILTER
Scaling filters can make jagged character outlines
smooth. The initial setting is “1”. “2” makes it smoother.
When choose “OFF”, the filter is canceled.
CLAMP START, CLAMP WIDTH
INPUT MEMORY > DETAIL > CLAMP START, CLAMP
WIDTH
Analog
Clamp pulse start positions and the widths can be
adjusted in accordance with the input signals. Incorrect
clamp setting may make whole image darkened and
horizontal uneven tone lines may appear on the image.
MASK START, MASK END
INPUT MEMORY > DETAIL > MASK START, MASK END
Analog
Synchronous mask start / end position can be adjusted.
In 3-line (sync on green) or 4-line (composite sync)
input, distorted images on the upper or lower part of
the image can be improved.
FRAME LOCK
INPUT MEMORY > DETAIL > FRAME LOCK
The signal frequency of the monitor can be locked to
synchronize with an input signal. The initial setting is
OFF.
Specify only one input signal to synchronize with. All
windows on the monitor will be synchronized with that
signal. If multiple signals are specified, all images will
be syncronized with one of those signals.
•
Normally, set it in FRAME LOCK menu in system
memory (page 35). When this menu in system
momory is ON, the syncronization setting follows the
system momory regardless of the input memory
setting.
FILM MODE
INPUT MEMORY > DETAIL > FILM MODE
The Film mode can be set when ADAPTIVE mode is
selected in INTERLACE menu. The initial setting is AUTO.
n
AUTO: detect 2-3 / 2-2 pull-down signal
automatically
n
OFF: turn off 2-3 / 2-2 pull-down signal processing.