REV 2.4
89
3.2.3. System
memory
The items within parentheses are initial values.
Item
Description
Page
MAINTENANCE
CSC
OFF, 1, 2 (OFF)
CSC adjustment
44
TAGET
COLOR
SET TARGET COLOR
Color balance
target setting
47
SENSOR
OFF, STOP,
RUN (OFF)
SENSOR
SET INITIAL SENSOR DATA
Auto brightness
correction setting
47
TOP
-128 – 127 (0)
BOTTOM
-128 – 127 (0)
LEFT
-128 – 127 (0)
RIGHT
-128 – 127 (0)
TOP/LEFT
-128 – 127 (0)
GRADATION
(*4)
WHITE,
RED,
GREEN,
BLUE
TOP/RIGHT
-128 – 127 (0)
BOTTOM/LEFT
-128 – 127 (0)
BOTTOM/RIGHT
-128 – 127 (0)
Gradation
adjustment
46
CALIBRATION
Lamp position
auto calibration
43
CHANGE MODE
OFF, NORMAL,
LONG
(NORMAL)
Auto-lamp
change timing
setting
43
LAMP
CHANGE
(
C
C
h
h
a
a
n
n
g
g
e
e
r
r
)
HOT EXCHANGE
FORBID,
ALLOW
(FORBID)
Hot lamp swap
allowance
setting
43
MECH
ALIGNMENT
ZOOM, H-KEYSTONE, V-KEYSTONE, TILT,
H-POSITION, V-POSITION
Motorized 6-axis
adjustment
31
LAMP TIMER RESET
Lamp operating
time resetting
73
FILTER RESET (*3)
Filter used hours
resetting
84
INSTALLATION
R-LEVEL
0 – 127 (0)
G-LEVEL
0 – 127 (0)
BLACK
LEVEL
B-LEVEL
0 – 127 (0)
Black level
adjustment
44
R-GAIN
0 – 1000
G-GAIN
0 – 1000
WHITE
BALANCE
LOW, MIDDLE,
HIGH (MIDDLE)
B-GAIN
0 – 1000
White balance
adjustment
45
RED
-20 – 20 (0)
YELLOW
-20 – 20 (0)
GREEN
-20 – 20 (0)
CYAN
-20 – 20 (0)
BLUE
-20 – 20 (0)
MAGENTA
-20 – 20 (0)
COLOR
MATRIX:
USER
SATURATION
-5 – 5 (0)
Color matrix
adjustment
48
AUTO
GAIN
AMP GAIN
(In main input)
MANUAL GAIN
Analog input
gain setting
48
AUTO
GAIN
SCALER AMP
GAIN (*1)
MANUAL GAIN
Analog input
gain setting
49
DIRECTION FRONT,
REAR
Access direction
to inside
42
FILTER TIME (*3)
0 – 30000
(4000)
Warning interval
setting
84
LAMP
POWER
NORMAL, BRIGHT (NORMAL)
Lamp brightness
setting
37
MISC
FUNCTION
LAMP MODE
(
X
X
L
L
2
2
1
1
)
LONG LIFE, NORMAL, F-REDUCTION
(F-REDUCTION)
Lamp driving
mode setting
37
Summary of Contents for VS-50PH50U
Page 120: ......