2 SPECIFICATIONS
2.4 Range of Values per Output Format
45
2
2.4
Range of Values per Output Format
This section shows the range of values that can be output for each output format.
Integer type
The ranges of the values that can be represented in each integer type are as follows.
If device values or values after scaling exceed the range, they are rounded within the range.
• If the value exceeds the upper limit value, the upper limit value is output.
• If the value is lower than the lower limit value, the lower limit value is output.
Float type
The ranges of the values that can be represented in each float type are as follows.
*1 -1.79769313486231570E-308 with the report function.
*2 1.79769313486231570E-308 with the report function.
If device values or values after scaling exceed the range, the data is output as follows:
• If the value exceeds the upper limit value of positive value, '+Inf' is output.
• If the value is lower than the lower limit value of negative value, '-Inf' is output.
• For values in a range between the upper limit value of negative value and the lower limit value of positive
value, '0' is output.
Count/Time
The value ranges that can be represented when the output value other than "value" is specified with trigger logging of data
logging are as follows.
*1 A unit specified in the configuration tool is applied (in seconds or milliseconds).
Output format
Lower limit
Upper limit
Word [Signed]
-32768
32767
Double Word [Signed]
-2147483648
2147483647
Word [Unsigned]/Bit String [16-bit]
0
65535
Double Word [Unsigned]/Bit String [32-bit]
0
4294967295
16bit BCD
0000
9999
32bit BCD
00000000
99999999
Output
format
Negative values
Positive values
Lower limit
Upper limit
Lower limit
Upper limit
FLOAT [Single
Precision]
-3.438
-1.401298E-45
1.401298E-45
3.438
FLOAT [Double
Precision]
-1.79769313486308
-4.94065645841246544E-324
4.94065645841246544E-324
1.79769313486308
Output format
-Inf
0
+Inf
FLOAT [Single Precision]
0xff800000
0x00000000
0x7f800000
FLOAT [Double Precision]
0xfff0000000000000
0x0000000000000000
0x7ff0000000000000
Output value
Lower limit
Upper limit
Value
Count
0
4294967295
Total count
0
4294967295
Time
0
4294967295
Total time
0
4294967295
Summary of Contents for RD81DL96
Page 2: ......
Page 80: ...78 7 INSTALLATION AND UNINSTALLATION 7 2 Uninstallation Procedure MEMO ...
Page 115: ...8 OPERATION EXAMPLE 8 3 Creating Reports from Continuously Logged Data 113 8 MEMO ...
Page 117: ...APPX Appendix 1 External Dimensions 115 A MEMO ...
Page 119: ...I 117 MEMO ...
Page 123: ......