3 - 13 3 - 13
MELSEC-Q
3 SPECIFICATIONS
Address
Hexadecimal Decimal
Details
Read/write from
CPU module
30
H
48
(A-slaves) Output Data To Slave Address 1A-3A
31
H
49
(A-slaves) Output Data To Slave Address 4A-7A
32
H
50
(A-slaves) Output Data To Slave Address 8A-11A
33
H
51
(A-slaves) Output Data To Slave Address 12A-15A
34
H
52
(A-slaves) Output Data To Slave Address 16A-19A
35
H
53
(A-slaves) Output Data To Slave Address 20A-23A
36
H
54
(A-slaves) Output Data To Slave Address 24A-27A
37
H
55
(A-slaves) Output Data To Slave Address 28A-31A
38
H
56
(B-slaves) Output Data To Slave Address 1B-3B
39
H
57
(B-slaves) Output Data To Slave Address 4B-7B
3A
H
58
(B-slaves) Output Data To Slave Address 8B-11B
3B
H
59
(B-slaves) Output Data To Slave Address 12B-15B
3C
H
60
(B-slaves) Output Data To Slave Address 16B-19B
3D
H
61
(B-slaves) Output Data To Slave Address 20B-23B
3E
H
62
(B-slaves) Output Data To Slave Address 24B-27B
3F
H
63
(B-slaves) Output Data To Slave Address 28B-31B
Writing enabled
40
H
to 48
H
64 to 72
Not used
49
H
to 4A
H
73 to 74
(A-slaves) List of Projected Slaves (LPS (For Write))
4B
H
to 4C
H
75 to 76
(B-slaves) List of Projected Slaves (LPS (For Write))
Writing enabled
4D
H
to 54
H
77 to 84
Not used
55
H
85
Command Buffer: <Request (Command)>
56
H
to 59
H
86 to 89
Command Buffer: <Request (data word 0 to 3(Command))>
Writing enabled
5A
H
to BF
H
90 to 191 Not used
C0
H
to C5
H
192 to 197 Current Error Code, Error Code History 1-5
C6
H
198
EEPROM
Write
Status
Reading enabled
C7
H
to CF
H
199 to 207 Not used
D0
H
to D1
H
208 to 209 (A-slaves) List of Peripheral Faults (LPF)
D2
H
to D3
H
210 to 211 (B-slaves) List of Peripheral Faults (LPF)
Reading enabled
D4
H
to DF
H
212 to 223 Not used
E0
H
to 15F
H
224 to 351 Analog Input Data (Slave Address 1-31)
160
H
to 1DF
H
352 to 479 Analog Output Data (Slave Address 1-31)
1E0
H
to 1FF
H
480 to 511 (A-slaves) Number of I/O Points
Reading enabled
200
H
to 21F
H
512 to 543 (B-slaves) Number of I/O Points
220
H
to 2FF
H
544 to 767 Not used
300
H
to 36D
H
768 to 877 Extended Command Buffer <Result>
Reading enabled
36E
H
to 3FF
H
878 to 1023 Not used
400
H
to 46D
H
1024 to 1133 Extended Command Buffer <Request(Data)>
Writing enabled
46E
H
to 7FF
H
1134 to 2047 Not used
Downloaded from