OPERATING PROCEDURE
Photo 13
Reactor
Screws
2
Connectors of
reactor
13. Removing the reactor (DCL)
(1) Remove the service panel. (See Photo 1)
(2) Disconnect the lead wires from the reactor. (See Photo5)
(3) Disconnect the connectors of reactor on the bottom plate of
the electrical parts box. (See Photo13)
(4) Remove 4 screws
2
on the bottom plate of the electrical
parts box. (See Photo 13)
(5) Remove the reactor.
Bottom plate of
electrical parts
box
OCH575