14
15
OCH724
TO
OUTDOOR
UNIT
SYMBOL
NAME
SYMBOL
NAME
SYMBOL
NAME
I.B
INDOOR CONTROLLER BOARD
FUSE FUSE (T6.3AL250V)
CN2L CONNECTOR (LOSSNAY)
CN32 CONNECTOR (REMOTE SWITCH)
CN41 CONNECTOR (HA TERMINAL-A)
CN51 CONNECTOR (CENTRALLY CONTROL)
CN105 CONNECTOR (IT TERMINAL)
POWER SUPPLY (R.B)
LED1 POWER SUPPLY (I.B)
LED2
TRANSMISSION (INDOOR-OUTDOOR)
LED3
WIRED REMOTE CONTROLLER BOARD
TERMINAL BLOCK (REMOTE CONTROLLER
TRANSMISSION LINE)
R.B
TB6
BZ
PCB FOR WIRELESS REMOTE CONTROLLER
BUZZER
LED1 LED (OPERATION INDICATION: GREEN)
RU
RECEIVING UNIT
SW1
EMERGENCY OPERATION (HEAT)
SW2
EMERGENCY OPERATION (COOL)
OPTION PARTS
W.B
DCL
MF
ML
LOUVER MOTOR
FAN MOTOR
REACTOR
TB2
TERMINAL BLOCK
(INDOOR/OUTDOOR CONNECTING LINE)
TB4
TERMINAL BLOCK
option for PSA-M.KA models.
ROOM TEMPERATURE THERMISTOR
(0
:
/15kΩ, 25
:
/5.4kΩ DETECT)
PIPE TEMPERATURE THERMISTOR/LIQUID
(0
:
/15kΩ, 25
:
/5.4kΩ DETECT)
COND./EVA. TEMPERATURE THERMISTOR
(0
:
/15kΩ, 25
:
/5.4kΩ DETECT)
TH1
TH2
TH5
[NOTES]
1. Symbols used in wiring diagram above are,
: Terminal (block), : Connector.
2. Indoor and outdoor connecting wires are made with
polarities, make wiring matching terminal numbers
(S1,S2,S3).
3. Since the outdoor side electric wiring may change be
sure to check the outdoor unit electric wiring for servicing.
4. This diagram shows the wiring of Indoor and Outdoor
connecting wires (specification of 230V),
adopting superimposed system of power and signal.
*
When work to supply power separately to Indoor and
Outdoor unit was applied, refer to Fig. 1.
For power supply system of this unit, refer to the caution
label located near this diagram.
1
3
5
1
4
1
CN22
(BU)
CN32
(WH)
CN51 (WH)
CN41 (WH)
CN2L
(RD)
OFF ON
SWE
CN20
(RD)
CN44
(WH)
PAIR No.
J42 J41
SW2
LED3
LED2
LED1
t°
t°
t°
TH2
TH5
TH1
TRANSMISSION
WIRE
DC12V
TB6
R.B
I.B
1
4
2
1
2 1
2
1
SW5
7
4
1
X2
ML
M
1~
3~
MF
CNP
(BU)
FUSE
POWER SUPPLY
~ (1 PHASE)
230V 50Hz
YE
OG
OG
BN
YE
OG
CN3C
(BU)
+
−
CNMF
(WH)
MS
1
3
1
3
*
*
5 3 1
CN01
(BK)
TB4
S1
S2
S3
2
BK
TO
OUTDOOR
UNIT
CN01
(BK)
CN3C
(BU)
1
3
5
BU
GNYE
RD
OG
YE
YE
I.B
TB2
OG
OG
YE
BN
1
3
S1
S2
S3
L
N
TB4
<Fig.1>
Refer to Table 1
for service PCB
Manufacture/Service
SW2
Table 2
1 2 3 4 5
CAPACITY
Manufacture/Service
CAPACITY
71
100
125
140
ON
OFF
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
Table 1
DCL
DCL
CN105
(RD)
SW5
ON
OFF
1 2 3 4 5 6 7 8
Refer to Table 2
for service PCB
4
6
1
CN4F
(WH)
Refrigerant sensor
CNSA
(WH)
4
1
1
4
CN90
(WH)
CN1
(WH)
RU
LED1
SW2
SW1
CN1
9
BZ
W.B
RD
BK
YE WH
RD BK
YE
WH
Manufacture/Service
SW2
SWITCH (CAPACITY CODE) Refer to <Table 1>.
SW5
SWITCH (FUNCTION SETTING) Refer to <Table 2>.
SWE
SWITCH (EMERGENCY OPERATION)
X2
RELAY (LOUVER)
The black square (■) indicates a
switch position.
A
B
WIRING DIAGRAM
7