e n
3
1 - 5 . I N S T A L L A T I O N D I A G R A M
Units should be installed by licensed contractor according to
local code requirements.
After the leak test, apply insulat-
ing material tightly so that there
is no gap.
When the piping is to be attached to
a w all containing metals (tin plated)
or metal netting, use a chemically
treated w ooden piece 25/32 in. (20
mm) or thicker betw een the w all
and the piping or w rap 7 to 8 turns
of insulation vinyl tape around
the piping.
To use existing piping, perform
COOL operation for 30 minutes
and pump do n before removing
the old air conditioner. Rema e flare
according to the dimension for new
refrigerant.
P A R T S T O B E P R O V I D E D A T Y O U R S I T E
(A) Pow er supply cord*
1
(B) Indoor/outdoor unit connecting w ire*
1
(C) Extension pipe
1
(D)
Wall hole cover
1
(E) Piping tape
1
(F)
Extension drain hose (or soft PVC
hose, 19/32 in. (15 mm) inner
diameter or hard PVC pipe VP16)
1
(G) Refrigeration oil
Little
amount
(H) Putty
1
(I)
Pipe fixing band
2 to 7
(J) Fixing screw for (I)
2 to 7
(K)
Wall hole sleeve
1
(L)
Soft PVC hose, 15 mm inner
diameter or hard PVC pipe VP16
for drain socket (1)
1
* N o t e :
Place indoor/outdoor unit connecting w ire (B) and
pow er supply cord (A) at least 3 ft. (1 m) aw ay from
the TV antenna w ire.
The ’ty for (B) to ( ) in the above table is quantity
to be used per indoor unit.
More than
3-15/16 in.
(100 mm)
Open as a rule
More than 19-11/16 in.
(500 mm) if the front
and both sides are open
More than 3-15/16 in. (100 mm)
More than 7-7/8 in. (200 mm) if there are
obstacles to both sides
Open as a rule
More than 19-11/16 in. (500 mm) if the
back, both sides and top are open
More than 13-25/32 in.
(350 mm)
O u t d o o r u n i t i n s t a l l a t i o n
Air inlet
Air outlet
Unit : inch
2 - 1 . I N S T A L L I N G T H E U N I T
Fix here w ith
M8 bolts.
Make the foundation
deeper.
Make the foundation
w ider.
• Be sure to fix the unit’s legs ith bolts hen installing it.
• Be sure to install the unit firmly to ensure that it does not fall by an earthqua e or a gust.
• Refer to the figure in the belo for concrete foundation.
O u t d o o r u n i t i n s t a l l a t i o n
33-1/16
19-11/16
6-21/32
4-13/32 × 13/16
oval holes (Base bolt M8)
Air inlet
13
14-3/16
15-19/32
Unit : mm
2 . O U T D O O R U N I T I N S T A L L A T I O N
Air inlet
169
500
Air inlet
396
Air outlet
840
361
330
4-10 × 21
oval holes (Base bolt M8)
VG79J997H01_01En.indd 3
2021/06/25 10:38:20