EN-2
EN
1-2. SELECTING THE INSTALLATION LOCATION
INDOOR UNIT
• Where airflow is not blocked.
• Where cool (or warm) air spreads over the entire room.
• Rigid wall without vibration.
• Where it is not exposed to direct sunshine. Do not
expose to direct sunshine also during the period fol-
lowing unpacking to before use.
• Where easily drained.
• At a distance 1 m or more away from your TV and ra-
dio. Operation of the air conditioner may interfere with
radio or TV reception. An amplifier may be required
for the affected device.
• In a place as far away as possible from fluorescent
and incandescent lights.
In order to make the infrared remote control operate
the air conditioner normally.
The heat from the lights may cause deformation or
the ultraviolet may cause deterioration.
• Where the air filter can be removed and replaced
easily.
• Where it is away from the other heat or steam source.
• Please ensure that the Router supports the WPA2-
AES encryption setting before commencement of
the installation of this indoor unit equipped with the
Wi-Fi interface.
• The End user should read and accept the terms and
conditions of the Wi-Fi service before commence
-
ment of the installation of this indoor unit equipped
with the Wi-Fi interface.
• This indoor unit equipped with the Wi-Fi interface
should not be installed and connected to any
Mitsubishi Electric system which is to provide
application critical cooling or heating.
REMOTE CONTROLLER
• Where it is easy to operate and easily visible.
• Where children cannot touch it.
• Select a position about 1.2 m above the floor and
check that signals from the remote controller are
surely received by the indoor unit from that position
(‘beep’ or ‘beep beep’ receiving tone sounds).
Note:
In rooms where inverter type fluorescent lamps are
used, the signal from the wireless remote controller
may not be received.
OUTDOOR UNIT
• Where it is not exposed to strong wind. If the outdoor
unit is exposed to a wind during defrosting, the defrost-
ing time will be longer.
• Where airflow is good and dustless.
• Where rain or direct sunlight can be avoided as much
as possible.
• Where neighbours are not annoyed by operation
sound or hot (or cool) air.
• Where rigid wall or support is available to prevent the
increase of operation sound or vibration.
• Where there is no risk of combustible gas leakage.
• When installing the unit at a high level, be sure to
secure the unit legs.
• Where it is at least 3 m away from the antenna of
TV set or radio. Operation of the air conditioner may
interfere with radio or TV reception in areas where
reception is weak. An amplifier may be required for
the affected device.
• Install the unit horizontally.
• Please install it in an area not affected by snowfall or
blowing snow. In areas with heavy snow, please install
a canopy, a pedestal and/or some baffle boards.
Note:
It is advisable to make a piping loop near outdoor unit
so as to reduce vibration transmitted from there.
Note:
When operating the air conditioner in low outside
temperature, be sure to follow the instructions de
-
scribed below.
• Never install the outdoor unit in a place where
its air inlet/outlet side may be exposed directly to
wind.
• To prevent exposure to wind, install the outdoor
unit with its air inlet side facing the wall.
• To prevent exposure to wind, it is recommended
to install a baffle board on the air outlet side of the
outdoor unit.
Avoid the following places for installation where air
conditioner trouble is liable to occur.
• Where flammable gas could leak.
• Where there is much machine oil.
• Where oil is splashed or where the area is filled
with oily smoke (such as cooking areas and fac-
tories, in which the properties of plastic could be
changed and damaged).
• Salty places such as the seaside.
• Where sulfide gas is generated such as hot spring,
sewage, waste water.
• Where there is high-frequency or wireless equip-
ment.
• Where there is emission of high levels of VOCs,
including phthalate compounds, formaldehyde,
etc., which may cause chemical cracking.
• The appliance shall be stored so as to prevent
mechanical damage from occurring.
1-3. SPECIFICATIONS
Model
Power supply *1
Wire specifications
Pipe size
(thickness *3, *4) Maximum amount of
refrigerant charge *7
Indoor unit
Outdoor unit
Rated Voltage
Frequency
Breaker
capacity
Power supply *2
Indoor/outdoor
connecting wire *2
Gas / Liquid
MSZ-AP15VG(K)
MUZ-AP15VG
230 V
50 Hz
10 A
3-core
1.0 mm²
4-core
1.0 mm²
ø9.52 / 6.35 mm
(0.8 mm)
740 g
MSZ-AP20VG(K)
MUZ-AP20VG
800 g
Pipe length and height difference
Max. pipe length
20 m
Max. height difference
12 m
Max. number of bends *5, *6
10
Refrigerant adjustment A *7
20 g/m
Insulation thickness *8, *9
8 mm
*1 Connect to the power switch which has a gap of 3 mm or more when open to interrupt the source power phase.
(When the power switch is shut off, it must interrupt all phases.)
*2 Use wires in conformity with design 60245 IEC 57.
*3 Never use pipes with thickness less than specified. The pressure resistance will be insufficient.
*4 Use a copper pipe or a copper-alloy seamless pipe.
*5 Be careful not to crush or bend the pipe during pipe bending.
*6 Refrigerant pipe bending radius must be 100 mm or more.
*7 If pipe length exceeds 7.5 m, additional refrigerant (R32) charge is required. (No additional charge is required for
pipe length less than 7.5 m.)
Additional refrigerant = A × (pipe length (m) – 7.5)
*8 Insulation material : Heat resisting foam plastic 0.045 specific gravity
*9 Be sure to use the insulation of specified thickness. Excessive thickness may cause incorrect installation of the
indoor unit and insufficient thickness may cause dew drippage.
WARNING
The unit should be installed in rooms which
have the floor space specified below.
AP15/20: 2.0
m²
When the indoor unit is connected to the multi
type outdoor unit of R32 refrigerant, please
consult your dealer about the floor space speci
-
fied.
As for the details, please refer to the Installation
Service Manual for New Refrigerant System.
CAUTION
(Could lead to serious injury in particular environments when operated incorrectly.)
n
Install an earth leakage breaker depending on
the installation place.
If an earth leakage breaker is not installed, it could
cause electric shock.
n
Perform the drainage/piping work securely ac-
cording to the installation manual.
If there is defect in the drainage/piping work, water
could drop from the unit, soaking and damaging
household goods.
n
Do not touch the air inlet or the aluminum fins
of the outdoor unit.
This could cause injury.
n
Do not install the outdoor unit where small
animals may live.
If small animals enter and touch the electric parts
inside the unit, it could cause a malfunction, smoke
emission, or fire. Also, advise user to keep the area
around the unit clean.
n
Do not operate the air conditioner during interior
construction and finishing work, or while waxing
the floor.
Before operating the air conditioner, ventilate the
room well after such work is performed. Otherwise, it
may cause volatile elements to adhere inside the air
conditioner, resulting in water leakage or scattering
of dew.
n
To prevent damage from static electricity, touch
a nearby metal body to discharge static electric-
ity from yourself before touching the indoor unit
equipped with the Wi-Fi interface.
Static electricity from the human body may damage
the Wi-Fi interface unit.
n
Do not use the indoor unit equipped with the
Wi-Fi interface nearby other wireless devices,
microwaves, cordless phones, or facsimiles.
It can cause malfunctions.
JG79N184H01_01En.indd 2
2021/03/17 14:50:24