66
EMERGENCY OPERATION switch
WASH
reset
E.O.
SW
Operation mode
COOL
HEAT
Set temperature
24
:
24
:
Fan speed
Medium
Medium
Horizontal vane
Auto
Auto
Vertical vane
Straight
Straight
The operation mode is indicated by the Operation In-
dicator lamp on the indoor unit as following figure.
Operation Indicator lamp
NOTE:
This is the indication of EMERGENCY OPERATION
mode. AREA setting is not available during EMER-
GENCY OPERATION.
Press again <Heat>
Press once <Cool>
Lighted
Not lighted
Press once again <Stop>
5-13. EMERGENCY / TEST OPERATION
In case of test run operation or emergency operation, use EMERGENCY OPERATION switch on the front of the indoor
unit. Emergency operation is available when the remote controller is missing, has failed or the batteries of the remote
controller run down. The unit will start and AREA lamp will light.
The first 30 minutes of operation is the test run operation. This operation is for servicing. The Indoor fan speed runs at
High speed and the system is in continuous operation (The thermostat in ON).
After 30 minutes of test run operation, the system shifts to EMERGENCY COOL / HEAT MODE with a set temperature of
24°C. The fan speed shifts to Med..
The coil frost prevention works even in emergency operation, and defrosting too.
In the test run or emergency operation, the horizontal vane operates in VANE AUTO (
) mode.
Emergency operation continues until EMERGENCY OPERATION switch is pressed once or twice or the unit receives any
signal from the remote controller. In case of latter, normal operation will start.
NOTE1 : Do not press EMERGENCY OPERATION switch during normal operation.
NOTE2 : 3 seconds after EMERGENCY OPERATION switch is pressed, the front panel starts moving forward
automatically.
PROGRAM TIMER
(Example 1) The current time is 8:00 PM.
The unit turns off at 11:00 PM, and on at 6:00 AM.
• The OFF timer and ON timer can be used in combination. The timer of the set time that is reached first will operate first.
• “
” and “
” display shows the order of the OFF timer and the ON timer operation.
(Example 2) The current time is 11:00 AM.
The unit turns on at 5:00 PM, and off at 9:00 PM.
NOTE : If the main power is turned off or a power failure occurs while AUTO START/STOP timer is active, the timer setting is
cancelled. As these models are equipped with an auto restart function, the air conditioner starts operating with timer
cancelled when power is restored.