![Mitsubishi Electric MSC-CA20VB Service Technical Manual Download Page 101](http://html.mh-extra.com/html/mitsubishi-electric/msc-ca20vb/msc-ca20vb_service-technical-manual_1810424101.webp)
101
❈
1 When the system is restarted with the remote controller, the system operates with the previous set temperature regard-
less of the room temperature at restart.
The set temperature is calculated by the previous set temperature.
(5) TEMPERATURE buttons
In “I FEEL CONTROL”( ) mode, set temperature is decided by the microprocessor based on the room temperature.
In addition, set temperature is controlled by TOO WARM or TOO COOL buttons when you feel too warm or too cool. Each
time TOO WARM or TOO COOL button is pressed, the indoor unit receives the signal and emits a beep tone.
• Fuzzy control
When TOO COOL or TOO WARM button is pressed, the microprocessor changes the set temperature, considering the
room temperature, the frequency of pressing TOO COOL or TOO WARM button and the user’s preference to heat or
cold. So this is called “Fuzzy control”, and works only in “I FEEL CONTROL” mode.
In DRY mode of “I FEEL CONTROL”, the set temperature doesn’t change.
…To raise the set temperature 1~2 (°C)
…To lower the set temperature 1~2 (°C)
(4) The initial set temperature is decided by the initial room temperature.
Model
DRY mode of
“I FEEL CONTROL”
Initial room temperature
13°C to 25°C
Initial set temperature
Initial room temperature
minus 2°C
COOL mode of
“I FEEL CONTROL”
❈
1
26°C or more
25°C to 26°C
24°C
Initial room temperature
minus 2°C
3. Coil frost prevention
①
Temperature control
When the indoor coil thermistor RT12 reads 1
:
(MCF-GA35VB)/ -1
:
(MCF-GA50/GA60VB) or below, the coil frost
prevention mode starts immediately. However the coil frost prevention doesn’t work for 5 minutes since the compressor
has started.
The indoor fan operates at the set speed the compressor stops for 5 minutes.
After that, if RT12 still reads below 1
:
(MCF-GA35VB)/ -1
:
(MCF-GA50/GA60VB) this mode is prolonged until
RT12 reads over 1
:
(MCF-GA35VB)/ -1
:
(MCF-GA50/GA60VB).
Difference between room
temperature and set
temperature
during operation ( T)
TOO
COOL
TOO
WARM
7-1-1. COOL mode of “I FEEL CONTROL”
-0.3
:
0.3
:
1. Thermostat control
Thermostat is ON or OFF by difference between room temperature and set temperature.
Initial temperature difference Thermostat
Room temperature minus set temperature : 0.3
:
or more················································ON
Room temperature minus set temperature : less than -0.3
:
············································OFF
Set temperature
Difference between room
temperature and set tem-
perature during operation
2. Indoor fan speed control
Indoor fan operates continuously at the set speed by FAN SPEED CONTROL button
regardless of the thermostat’s OFF-ON.
In AUTO the fan speed is as follows.
Room temperature minus set temperature : 1.7
:
or more ········································High
Room temperature minus set temperature : Between 1 and 1.7
:
··································Med.
Room temperature minus set temperature : less than 1
:
········································Low
1.7
:
(0.7
:
)
W
3
:
(1.7
:
)
W
1
:
(0
:
)
W
Initial temperature difference
Fan speed
ww
In case that
T has been any following condition for 30 minutes, the value in the parentheses is applied.
a. Fan speed is Auto Low, and
T is 1
:
or more.
b. Fan speed is Auto Med., and
T is 1.7
:
or more.