3. Operation
■
Manual vane angle (Vertical air direction) (Wired remote controller)
Select “Comfort” from the Operation
menu, and press the [SELECT] but-
ton.
Select “Manual vane angle” with the
[F1] or [F2] button, and press the
[SELECT] button.
Main menu:
Cursor
Operation
Vane·Louver·Vent. (Lossnay)
High power
Comfort
F1
F2
F3
F4
Setting display:
Cursor
Comfort
Manual vane angle
3D i-See sensor
F1
F2
F3
F4
Setting display:
Cursor
Airflow direction setting
Vertical
Horizontal
F1
F2
F3
F4
Manual vane angle
Input display:
Cur.
Address
Ref. address
Unit No.
Identify unit Check button
Check
F1
F2
F3
F4
Manual vane angle
Cur.
Angle
Ref. address
Unit No.
Vane
4-way
/2-way
Cursor
Input display:Angle button
F1
F2
F3
F4
Move the cursor to “Ref. address”
or “Unit No.” with the [F1] button to
select.
Select the refrigerant address and
the unit number for the units to
whose vanes are to be fixed, with
the [F2] or [F3] button, and press the
[SELECT] button.
• Ref. address: Refrigerant ad-
dress
• Unit No.: 1, 2, 3, 4
Press the [F4] button to confirm the
unit.
Select “Vane” with the [F1] button.
Select “4-way” or “2-way” with the
[F2] or [F3] button, and press the
[F4] button.
Outlet No. 2
Outlet No. 3
Outlet No. 1
Outlet No. 4
Remote controller setting
The airflow direction of this outlet
is controlled by the airflow direc
-
tion setting of remote controller.
Fixed
The airflow direction of this outlet is fixed
in particular direction.
* When it is cold because of direct
airflow, the airflow direction can be
fixed horizontally to avoid direct airflow.
Notes:
●
During swing operation, the directional indication on the screen
does not change in sync with the directional vanes on the unit.
●
Available directions depend on the type of unit connected.
●
In the following cases, the actual air direction will differ from the
direction indicated on the remote controller display.
1. While the display is in “Standby” or “Defrost” states.
2. Immediately after starting heat mode (while the system is wait
-
ing for the mode change to take effect).
3. In heat mode, when room temperature is higher than the tem
-
perature setting.
< How to set the fixed up/down air direction >
For PLA-EA series, only the particular outlet can be fixed to certain direc
-
tion with the procedures below. Once fixed, only the set outlet is fixed
every time air conditioner is turned on. (Other outlets follow UP/DOWN air
direction setting of remote controller.)
Note:
This function cannot be set depending on the outdoor unit to be
connected.
■
Explanation of word
• “Refrigerant address No.” and “Unit No.” are the numbers given to
each air conditioner.
• “Outlet No.” is the number given to each outlet of air conditioner.
(Refer to the illustration below.)
•
“Up/Down air direction” is the direction (angle) to fix.
Horizontal airflow
Note:
The outlet No. is indicated by the number of grooves on both
ends of each air outlet. Set the air direction while checking the
information shown on the remote controller display.
Air outlet identification marks
Select “Vertical” with the [F1] or [F2]
button, and press the [SELECT] but-
ton.
* This screen appears only when
the horizontal air direction func-
tion is supported.
GG79D031H01_01en.indd 9