60
OPERATING PROCEDURE
PHOTOS
3. Removing the compressor
(1) Remove the lead clamps.
(2) Remove the screws securing the relay panel.
(3) Remove the screw securing the service port.
(4) Remove the terminal cover.
(5) Pull out the lead from the compressor terminal.
(6) Remove the overcurrent relay.
(7) Remove the compressor nuts.
(8) Detach the suction pipe welded section and discharge pipe
welded section with a burner.
NOTE
●
Before using a torch, rechin gas from the pipes until the pres-
sure gauge shows 0 PSIG.
●
Use the burner under the condition that gas can be released
even when the inner pressure rises by heat.
●
Reclain all refrigerant in an environmentally acceptable man-
ner.
Photo 4
Terminal cover
Discharge pipe
compressor
Suction pipe
OB198--2.qxp 24/6/97 6:05 AM Page 60