45
11-2-1 troubleshooting check table
❈
Before taking measures, make sure that the symptom reappears, for accurate troubleshooting.
Self check table
NO.
1
2
3
4
Abnormal
point
Mis-wiring
Serial sig-
nal
Indoor coil
thermistor
Room
tempera-
ture ther-
mistor
Indoor fan
motor
Outdoor
thermistor
Indication
1-second ON
1-second OFF
1-second ON
2.5-second OFF
2-time flash
2.5-second OFF
3-time flash
2.5-second OFF
6-time flash
2.5-second OFF
Symptom
Outdoor unit
does not run.
Outdoor unit
does not run.
Indoor fan
repeats 12 sec-
onds ON and 3
minutes OFF.
When the indoor
fan breaks, the
fan keeps stop-
ping.
Outdoor unit
does not run
Detect method
When serial signal stops for 4
to 5 seconds after 1st on of
52C relay by POWER turning
on.
When serial signal from out-
door unit stops for 4 to 5 sec-
onds.
Detects Indoor coil/room tem-
perature thermistor short or
open circuit every 2 seconds
during operation.
When rotational frequency
feedback signal is not emit
during 12-second indoor fan
operation.
When the outdoor thermistor
shorts or opens after the com-
pressor start-up.
Check point
●
Check wiring (visual sheck and conductiv-
ity check).
●
Check indoor electronic control P.C.
board.
●
Check outdoor DEICER P.C. board.
●
Check electrical parts.
●
Check thermistor calibretion.
●
Reconnect connector.
●
Check indoor borad.
●
Disconnect connector CN211 and then
check connector CN121 - to make
sure rotational frequency feedback signal
of 1.5V or over exists.
●
Check indoor electronic control P.C.
board.
●
Check indoor fan motor.
●
Reconnect conector.
●
Check outdoor DEICER P.C. board.
●
Check thermistor calibretion.
2
3
MSH09NW only
Look at the left lamp flash for the self check table.