54
RELAY OPERATION
MSH09NW
MSH12NN
MSH15NN
MSH17NN
MODE
THERMOSTAT
52C CONTACTOR
INDOOR FAN RELAY
COOL &
COOL mode
of I FEEL
CONTROL
DRY &
DRY mode
of I FEEL
CONTROL
HEAT &
HEAT mode
of I FEEL
CONTROL
ON
OFF
OFF
OFF
ON
ON
ON
OFF
ON
OFF
OFF for 2 min.after
system
Repeats 8 min. ON/3min. OFF
operation or 2 min. ON/3 min.
OFF operation
Repeates 4 min. OFF/1
min. ON operation
AUTO or set speed
AUTO or set
AUTO or set speed links with 52C con-
tactor.
AUTO or set speed
VLo speed
NOTE : When the compressor is OFF, “3-minute time delay circuit” operates.
COIL FROST PREVENTION mode are as follows
MODE
THERMOSTAT
52C CONTACTOR
INDOOR FAN RELAY
COOL &
COOL mode
of I FEEL
CONTROL
DRY &
DRY mode
of I FEEL
CONTROL
ON
Off for 5 min. After
that, OFF is pro-
longed until indoor
coil thermistor reads
termination temper-
ature.
AUTO or set speed
VLo speed
Indoor fan relay mode (MSH12NN,MSH15NN)
Indoor fan speed
Hi
Me
Lo
VLo
OFF
Relay turning ON
SR144
SR143
SR142
SR141
All fan relays are off
OB198--2.qxp 24/6/97 6:03 AM Page 54
Summary of Contents for Mr. Slim MSH09NW
Page 2: ......
Page 72: ...72 1 3 8 11 4 2 13 14 6 7 9 10 17 19 20 15 16 5 OUTDOOR UNIT STRUCTURAL PARTS MUH17NN 18 21 ...
Page 75: ......