2 APPENDIX
2.1 CC-Link IE TSN
39
2
• Status DO 5
*1 Available on servo amplifiers with firmware version B2 or later.
• Status DO 6
Bit
Symbol
Description
Reference
0
The value at reading is undefined.
1
2
3
4
S_CDPS2
Variable gain enabled 2
Refer to "GAIN SWITCHING
FUNCTION" in the following
manual.
MR-JET User's Manual
(Adjustment)
5
S_CPO
Rough match
When the command remaining distance is less than the value of the rough match output range
set in [Pr. PT12], S_CPO is on.
This is not outputted during base circuit shut-off. When the servo amplifier is switched to the
servo-on state, S_CPO switches on.
6
The value at reading is undefined.
7
8
9
10
11
12
13
14
15
Bit
Symbol
Description
Reference
0
The value at reading is undefined.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15