2 APPENDIX
2.1 CC-Link IE TSN
19
2
■
Default PDO mapping
Default PDO mapping is the initial placement of objects included in a PDO. When there is no request from the controller or the
engineering tool to change PDO mapping objects, the servo amplifier operates using default PDO mapping.
• RPDO, TPDO 1st mapping ([1st Receive PDO Mapping (Obj. 1600h)] and [1st Transmit PDO Mapping (Obj. 1A00h)])
PDO mapping for cyclic synchronous operation (csp/csv/cst/hm).
RPDO (from the master station to the servo amplifier)
Offset Address
Index
Device name
0000h
1D01h
Watch dog counter DL
0002h
6060h
Modes of operation
0003h
0000h
GAP
0004h
607Ah
Target position
0008h
60FFh
Target velocity
000Ch
6040h
Controlword
000Eh
60E0h
Positive torque limit value
0010h
60E1h
Negative torque limit value
0012h
6071h
Target torque
0014h
2D20h
Velocity limit value
0018h
2D01h
Control DI 1
001Ah
2D02h
Control DI 2
001Ch
2D03h
Control DI 3
001Eh
2D04h
Control DI 4
0020h
2D05h
Control DI 5
0022h
0000h
GAP
TPDO (from the servo amplifier to the master station)
Offset Address
Index
Device name
0000h
1D02h
Watch dog counter UL
0002h
6061h
Modes of operation display
0003h
0000h
GAP
0004h
6064h
Position actual value
0008h
606Ch
Velocity actual value
000Ch
60F4h
Following error actual value
0010h
6041h
Statusword
0012h
0000h
GAP
0014h
6077h
Torque actual value
0016h
2D11h
Status DO 1
0018h
2D12h
Status DO 2
001Ah
2D13h
Status DO 3
001Ch
2D14h
Status DO 4
001Eh
2D15h
Status DO 5
0020h
2A41h
Current alarm
0024h
2D21h
Reserved
0028h
2D22h
Reserved