66
6 OPTIONS AND PERIPHERAL EQUIPMENT
6.2 Regenerative option
Refer to the following diagram and follow the steps (1) to (3) to remove the built-in regenerative resistor installed on the back
of MR-JET-40_ to MR-JET-300_.
(1) Pull out the power connector (CNP1). Do not forcibly pull the lead wires of the built-in regenerative resistor or the CNP1
connector. Doing so may snap the lead wires.
(2) Pull out the wires of the built-in regenerative resistor from the power connector (CNP1).
(3) Remove the wires of the built-in regenerative resistor from the servo amplifier. Carefully remove the wires to avoid
snapping them.
(4) Remove the screws (screw size: M3) used to fix the built-in regenerative resistor and take out the built-in regenerative
resistor. Keep the removed built-in regenerative resistor and the removed screws as necessary. To install the regenerative
resistor again, tighten the screws with a tightening torque of 0.72 N•m.
(4)
(3)
(2)
(1)