5 CHARACTERISTICS
5.3 Dynamic brake characteristics
53
5
Dynamic brake time constant
The following shows dynamic brake time constant
that is necessary to calculate the equation (5.2).
■
HG-KNS/HG-SNS
Permissible load to motor inertia when the dynamic brake is used
Use the dynamic brake under the load to motor inertia ratio indicated in the following table. If the ratio is higher than this value,
the dynamic brake may burn. If the ratio exceeds the value, contact your local sales office.
The values of the permissible load to motor inertia ratio in the table are the values at the maximum speed of the servo motor.
Servo motor
Waveform
HG-KNS13_
HG-KNS23_
HG-KNS43_
HG-KNS73_
HG-SNS52_
HG-SNS102_
HG-SNS152_
HG-SNS202_
HG-SNS302_
Servo motor
Permissible load to motor inertia ratio [multiplier]
HG-KNS13_
30
HG-KNS23_
HG-KNS43_
HG-KNS73_
HG-SNS52_
HG-SNS102_
HG-SNS152_
HG-SNS202_
24
HG-SNS302_
16
73
13
43
23
0
10
20
30
40
50
60
0
1000 2000 3000 4000 5000 6000
Servo motor speed [r/min]
Dynamic brake time constant
τ
[ms]
0
40
120
100
80
60
20
140
160
180
200
0
500
1000 1500 2000 2500 3000
102
52
202
302
152
Servo motor speed [r/min]
Dynamic brake time constant
τ
[ms]
Summary of Contents for Melservo-Jet MR-JET G-N1 Series