![Mitsubishi Electric Melservo-Jet MR-JET G-N1 Series User Manual Download Page 38](http://html.mh-extra.com/html/mitsubishi-electric/melservo-jet-mr-jet-g-n1-series/melservo-jet-mr-jet-g-n1-series_user-manual_240844038.webp)
36
3 SIGNALS AND WIRING
3.5 Signal (device) explanation
Power supply
Power supply explanations
■
DICOM (Digital input I/F power supply)
Input 24 V DC (24 V DC ± 10 %, 300 mA) for I/O interfaces. The power supply capacity varies depending on the number of I/
O interface points to be used.
For sink interfaces, connect the positive terminal of the 24 V DC external power supply.
For source interfaces, connect the negative terminal of the 24 V DC external power supply.
■
DOCOM (Digital output I/F power supply)
Input 24 V DC (24 V DC ± 10 %, 300 mA) for I/O interfaces. The power supply capacity varies depending on the number of I/
O interface points to be used.
For sink interfaces, connect the negative terminal of the 24 V DC external power supply.
For source interfaces, connect the positive terminal of the 24 V DC external power supply.
■
SD (Shield)
Connect the external conductor of a shielded wire to SD.