JEP0-IL9416
14
A - 6 Self-diagnosis – status indication
This item is only displayed when the self-diagnosis function detects an abnormal condition. The item number 400 (in the
following example) will be skipped and moved straight from 010 to 511 in case of no detecting an abnormal condition.
<< Example >> To check the defect code after the following abnormal condition was detected by the self- diagnosis
function:
(1) RAM check fault ................................Defect code = 0002
(2) D/O operation check fault ..................Defect code = 0009
Operation
Step Description
Switch Press
Indication
1
The indication mode starts.
IND./IND.END
Once
0
0
0.
0
1
0
Item No.
Item data
A-
phase
B-
phase
C-
phase
Zero-
phase
kA
A
2
When the switch is kept depressed until
the item number “400” appears, the defect
code that is the smallest in number will be
indicated.
Ex. : RAM check fault is indicated.
UP
-
2
0
0
0
0
0
4
Item No.
Item data
A-
phase
B-
phase
C-
phase
Zero-
phase
kA
A
3
Another defect code that is the second
smallest will be displayed.
Ex. : D/O operation check fault is
indicated.
UP
Once
9
0
0
0
0
0
4
Item No.
Item data
4
Changing the item number to the next
“511” will indicate that there is no records
any more.
UP
Once
1
1
5
Item No.
Item data
5
The indication mode ends.
IND./IND.END
Once
Item No.
Item data