5-69
Maintenance and inspection procedures
5Maintenance and Inspection
Fig.5-11 : Replace the top bellows(RH-12SQH/18SQH series)
Replace the bellows in a place where there is no risk of contamination by dust and oil
mist. If it must be replaced in a dust-filled area, be sure to remove as much dust as
possible in advance before replacing it.
<1>
<2>
4-M3 x 8
No. 2 arm cover-U
A
M4 set screws x 2
Clamp ring
Top bellows
Liquid gasket coating position
<1>
<2>
4-M3 x 8 screw
Section A
Ball screw
10
Details of D cut surface
D cut surface
RH-6SDH series: φ20
RH-12SDH/18SDH series :φ25
CAUTION