3Installing the option devices
Installing the solenoid valve set (1S-VD04M(E)-03, 1S-VD04M(E)-04) 3-48
3 Installing the option devices
The installation of the solenoid valve set, the hand input cable, the hand output cable and retrieval of the spare
wiring require removal of the same cover. Therefore, it is better to install them simultaneously.
3.1 Installing the solenoid valve set
(1S-VD04M(E)-03, 1S-VD04M(E)-04)
Fig.3-1 : Solenoid valve installation procedures
shows the solenoid valve installation procedures and the solenoid valve connector connection procedures.
The installation procedures are as follow. This work must be carried out with the controller power turned OFF.
If the hand input cables (1S-HC35C-02) or the hand output cables (1S-GR35S-02) are used, be sure to install
them in advance.
(Refer to
"3.2Installing the hand input cable" on page 51
"3.3Installing the hand output cable" on page 52.
)
1
3
5
7
2
4
6
8
A port
B port
GR1
GR2
1
3
5
7
2
4
6
8
A port
B port
AIR IN
RETURN
Detail of section B
GR1
GR2
Detail of section A
Electrical wiring opening (grommet)
AIR OUT
RETURN
CON plate F
Section A
Section B
No.2 solenoid valve
No.3 solenoid valve
No.4 solenoid valve
<7>R port
<6>P port
Plate
GR7, GR5, GR3, GR1
In order from left side
No.1 solenoid valve
GR8, GR6, GR4, GR2
In order from left side
GR7, GR5, GR3, GR1
In order from left side
<7>R port
<6>P port
Plate
GR8, GR6, GR4, GR2
In order from left side
No.2 solenoid valve
No.3 solenoid valve
No.4
solenoid valve
No.1 solenoid valve
RH-6SQH series : 1S-VD04M(E)-04
RH-12SQH/18SQH series : 1S-VD04M(E)-03