WALL-MOUNTED Inverter Heat Pump
M series
PERFORMANCE DA
TA
W
ALL-
MOUNTED
C-139
Heat operation at Rated frequency
MSZ-GE25VA: MUZ-GE25VA MUZ-GE25VAH
CAPACITY: 3.2 kW
INPUT: 700 W
INDOOR
DB (°C)
OUTDOOR WB (°C)
-10
-5
0
5
10
15
20
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
15
2.02
455
2.43
546
2.85
616
3.26
665
3.68
707
4.06
728
4.48
742
21
1.92
490
2.30
581
2.72
644
3.10
693
3.52
728
3.90
749
4.30
777
26
1.73
525
2.14
616
2.53
679
2.94
728
3.36
763
3.74
784
4.16
805
MSZ-GE35VA: MUZ-GE35VA MUZ-GE35VAH
CAPACITY: 4.0 kW
INPUT: 955 W
INDOOR
DB (°C)
OUTDOOR WB (°C)
-10
-5
0
5
10
15
20
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
15
2.52
621
3.04
745
3.56
840
4.08
907
4.60
965
5.08
993
5.60
1012
21
2.40
669
2.88
793
3.40
879
3.88
945
4.40
993
4.88
1022
5.38
1060
26
2.16
716
2.68
840
3.16
926
3.68
993
4.20
1041
4.68
1070
5.20
1098
MSZ-GE42VA: MUZ-GE42VA MUZ-GE42VAH
CAPACITY: 5.4 kW
INPUT: 1460 W
INDOOR
DB (°C)
OUTDOOR WB (°C)
-10
-5
0
5
10
15
20
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
15
3.40
949
4.10
1139
4.81
1285
5.51
1387
6.21
1475
6.86
1518
7.56
1548
21
3.24
1022
3.89
1212
4.59
1343
5.24
1445
5.94
1518
6.59
1562
7.26
1621
26
2.92
1095
3.62
1285
4.27
1416
4.97
1518
5.67
1591
6.32
1635
7.02
1679
MSZ-GE50VA: MUZ-GE50VA MUZ-GE50VAH
CAPACITY: 5.8 kW
INPUT: 1565 W
INDOOR
DB (°C)
OUTDOOR WB (°C)
-10
-5
0
5
10
15
20
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
15
3.65
1017
4.41
1221
5.16
1377
5.92
1487
6.67
1581
7.37
1628
8.12
1659
21
3.48
1096
4.18
1299
4.93
1440
5.63
1549
6.38
1628
7.08
1675
7.80
1737
26
3.13
1174
3.89
1377
4.58
1518
5.34
1628
6.09
1706
6.79
1753
7.54
1800
MSZ-GE60VA: MUZ-GE60VA
CAPACITY: 6.8 kW
INPUT: 1770 W
INDOOR
DB (°C)
OUTDOOR WB (°C)
-10
-5
0
5
10
15
20
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
15
4.28
1151
5.17
1381
6.05
1558
6.94
1682
7.82
1788
8.64
1841
9.52
1876
21
4.08
1239
4.90
1469
5.78
1628
6.60
1752
7.48
1841
8.30
1894
9.15
1965
26
3.67
1328
4.56
1558
5.37
1717
6.26
1841
7.14
1929
7.96
1982
8.84
2036
MSZ-GE71VA: MUZ-GE71VA
CAPACITY: 8.1 kW
INPUT: 2110 W
INDOOR
DB (°C)
OUTDOOR WB (°C)
-10
-5
0
5
10
15
20
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
15
5.10
1372
6.16
1646
7.21
1857
8.26
2005
9.32
2131
10.29
2194
11.34
2237
21
4.86
1477
5.83
1751
6.89
1941
7.86
2089
8.91
2194
9.88
2258
10.89
2342
26
4.37
1583
5.43
1857
6.40
2047
7.45
2194
8.51
2300
9.48
2363
10.53
2427
NOTE:
Q : Total capacity (kW) INPUT : Total power input (W) DB: Dry-bulb temperature WB: Wet-bulb temperature
Summary of Contents for M-SERIES
Page 6: ...M series C WALL MOUNTED ...
Page 38: ...WALL MOUNTED Outdoor Unit M series WIRING DIAGRAM WALL MOUNTED C 36 MUH GD80VB OUTDOOR UNIT ...
Page 40: ...WALL MOUNTED Outdoor Unit M series WIRING DIAGRAM WALL MOUNTED C 38 OUTDOOR UNIT MUZ FD50VA ...
Page 42: ...WALL MOUNTED Outdoor Unit M series WIRING DIAGRAM WALL MOUNTED C 40 OUTDOOR UNIT MUZ FD50VABH ...
Page 45: ...WALL MOUNTED Outdoot Unit M series WIRING DIAGRAM WALL MOUNTED C 43 MUZ GE42VA OUTDOOR UNIT ...
Page 46: ...WALL MOUNTED Outdoor Unit M series WIRING DIAGRAM WALL MOUNTED C 44 MUZ GE42VAH OUTDOOR UNIT ...
Page 47: ...WALL MOUNTED Outdoot Unit M series WIRING DIAGRAM WALL MOUNTED C 45 MUZ GE50VA OUTDOOR UNIT ...
Page 48: ...WALL MOUNTED Outdoor Unit M series WIRING DIAGRAM WALL MOUNTED C 46 MUZ GE50VAH OUTDOOR UNIT ...
Page 50: ...WALL MOUNTED Outdoor Unit M series WIRING DIAGRAM WALL MOUNTED C 48 MUZ HC25VA OUTDOOR UNIT ...
Page 192: ...WALL MOUNTED Inverter Heat Pump M series INSTALLATION PROCEDURE WALL MOUNTED C 190 ...
Page 271: ...FLOOR STANDING MFZ KA VA Series M series OPERATION FLOOR STANDING C 269 ...
Page 272: ...FLOOR STANDING MFZ KA VA Series M series OPERATION FLOOR STANDING C 270 f i save OPERATION ...
Page 289: ...CEILING CASSETTE Inverter Heat Pump M series INSTALLATION PROCEDURE CEILING CASSETTE C 287 ...
Page 290: ...CEILING CASSETTE Inverter Heat Pump M series INSTALLATION PROCEDURE CEILING CASSETTE C 288 ...
Page 292: ...CEILING CASSETTE Inverter Heat Pump M series INSTALLATION PROCEDURE CEILING CASSETTE C 290 ...
Page 293: ...CEILING CASSETTE Inverter Heat Pump M series INSTALLATION PROCEDURE CEILING CASSETTE C 291 ...
Page 294: ...CEILING CASSETTE Inverter Heat Pump M series INSTALLATION PROCEDURE CEILING CASSETTE C 292 ...
Page 300: ...CEILING CASSETTE M series CEILING CASSETTE C 298 ...