WALL-MOUNTED Outdoor Unit
M series
NOISE CRITERIA
CUR
VES
W
ALL-
MOUNTED
C-147
C.1.7.2 Outdoor Unit
MU-GA20VB
MU-GA25VB
OUTDOOR UNIT
MU-GA35VB
OUTDOOR UNIT
90
80
70
60
50
40
30
20
10
63
125
250
500
1000
2000
4000
8000
NC-60
NC-50
NC-40
NC-30
NC-20
NC-10
NC-70
OCT
AVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 MICRO BAR
BAND CENTER FREQUENCIES, Hz
Test conditions,
Cooling :Dry-bulb temperature 35 ºC Wet-bulb temperature 24 ºC
COOLING
FUNCTION
49
SPL(dB
(A)
)
LINE
90
80
70
60
50
40
30
20
10
63
125
250
500
1000
2000
4000
8000
NC-60
NC-50
NC-40
NC-30
NC-20
NC-10
NC-70
OCT
AVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 MICRO BAR
BAND CENTER FREQUENCIES, Hz
Test conditions,
Cooling :Dry-bulb temperature 27 ºC Wet-bulb temperature 19 ºC
COOLING
FUNCTION
45
SPL(dB
(A)
)
LINE
90
80
70
60
50
40
30
20
10
63
125
250
500
1000
2000
4000
8000
NC-60
NC-50
NC-40
NC-30
NC-20
NC-10
NC-70
OCT
AVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 MICRO BAR
BAND CENTER FREQUENCIES, Hz
Test conditions,
Cooling :Dry-bulb temperature35°C Wet-bulb temperature24°C
MU-GE50VB
COOLING
FUNCTION
52
SPL(dB
(A)
)
LINE
OUTDOOR UNIT
Test conditions,
Cooling : Dry-bulb temperature 35
Wet-bulb temperature 24
MU-GA60VB
80
90
70
60
50
40
30
20
10
63
125
250
500
1000
2000
4000
8000
NC-60
NC-50
NC-40
NC-30
NC-20
NC-10
NC-70
OCT
AVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 MICRO BAR
BAND CENTER FREQUENCIES, Hz
High
FAN SPEED
COOLING
FUNCTION
53
SPL(dB
(A)
)
LINE
OUTDOOR UNIT
Summary of Contents for M-SERIES
Page 6: ...M series C WALL MOUNTED ...
Page 38: ...WALL MOUNTED Outdoor Unit M series WIRING DIAGRAM WALL MOUNTED C 36 MUH GD80VB OUTDOOR UNIT ...
Page 40: ...WALL MOUNTED Outdoor Unit M series WIRING DIAGRAM WALL MOUNTED C 38 OUTDOOR UNIT MUZ FD50VA ...
Page 42: ...WALL MOUNTED Outdoor Unit M series WIRING DIAGRAM WALL MOUNTED C 40 OUTDOOR UNIT MUZ FD50VABH ...
Page 45: ...WALL MOUNTED Outdoot Unit M series WIRING DIAGRAM WALL MOUNTED C 43 MUZ GE42VA OUTDOOR UNIT ...
Page 46: ...WALL MOUNTED Outdoor Unit M series WIRING DIAGRAM WALL MOUNTED C 44 MUZ GE42VAH OUTDOOR UNIT ...
Page 47: ...WALL MOUNTED Outdoot Unit M series WIRING DIAGRAM WALL MOUNTED C 45 MUZ GE50VA OUTDOOR UNIT ...
Page 48: ...WALL MOUNTED Outdoor Unit M series WIRING DIAGRAM WALL MOUNTED C 46 MUZ GE50VAH OUTDOOR UNIT ...
Page 50: ...WALL MOUNTED Outdoor Unit M series WIRING DIAGRAM WALL MOUNTED C 48 MUZ HC25VA OUTDOOR UNIT ...
Page 192: ...WALL MOUNTED Inverter Heat Pump M series INSTALLATION PROCEDURE WALL MOUNTED C 190 ...
Page 271: ...FLOOR STANDING MFZ KA VA Series M series OPERATION FLOOR STANDING C 269 ...
Page 272: ...FLOOR STANDING MFZ KA VA Series M series OPERATION FLOOR STANDING C 270 f i save OPERATION ...
Page 289: ...CEILING CASSETTE Inverter Heat Pump M series INSTALLATION PROCEDURE CEILING CASSETTE C 287 ...
Page 290: ...CEILING CASSETTE Inverter Heat Pump M series INSTALLATION PROCEDURE CEILING CASSETTE C 288 ...
Page 292: ...CEILING CASSETTE Inverter Heat Pump M series INSTALLATION PROCEDURE CEILING CASSETTE C 290 ...
Page 293: ...CEILING CASSETTE Inverter Heat Pump M series INSTALLATION PROCEDURE CEILING CASSETTE C 291 ...
Page 294: ...CEILING CASSETTE Inverter Heat Pump M series INSTALLATION PROCEDURE CEILING CASSETTE C 292 ...
Page 300: ...CEILING CASSETTE M series CEILING CASSETTE C 298 ...