4
4.
Command list
4.1 Operation commands
(Not executable in stand-by mode. When the commands for input select are sent
while the splash screen is being displayed, the splash screen is only canceled.)
The operation commands are used for the basic operation setting of this projector. They may not be executed
while the signals are changed. The operation commands have no data codes.
ITEM
Function
Note
Character
ASCII
POWER ON
!
21h
This command is invalid for 1 minute after the power is turned off.
POWER OFF
"
22h
This command is invalid for 1 minute after the power is turned on.
INPUT COMPUTER 1
_r1
5Fh 72h 31h
This command will not be executed in Stand-by mode or when the MUTE is executed.
INPUT COMPUTER 2
_r2
5Fh 72h 32h
This command will not be executed in Stand-by mode or when the MUTE is executed.
INPUT DVI
_d1
5Fh 64h 31h
This command will not be executed in Stand-by mode or when the MUTE is executed.
INPUT VIDEO
_v1
5Fh 76h 31h
This command will not be executed in Stand-by mode or when the MUTE is executed.
INPUT S-VIDEO
_v2
5Fh 76h 32h
This command will not be executed in Stand-by mode or when the MUTE is executed.
[Example] When setting the input signal to COMPUTER 1. (Figures and symbols enclosed in quotation marks
are ASCII codes.):
Sending commands
from the PC, etc.
Status code
from the projector
Description
‘30’ ‘30’ ‘5F’ ‘72’ ‘31’ ‘0D’
00_r1
Command for setting the input signal
to COMPUTER 1
‘30’ ‘30’ ‘5F’ ‘72’ ‘31’ ‘0D’
00_r1
Command receipt confirmation
(Command echo back)
4.2 Reading command diagram
The projectors operating status, such as POWER-ON/OFF and the currently selected input terminal, etc. can be
monitored.
ITEM
Character
ASCII
Function
Data (Receive)
Function
Data (Receive)
POWER ON
vP
1
76h 50h
31h
POWER OFF
vP
0
76h 50h
30h
INPUT COMPUTER 1
vI
r1
76h 49h
72h 31h
INPUT COMPUTER 2
vI
r2
76h 49h
72h 32h
INPUT DVI
vI
d1
76h 49h
64h 31h
INPUT VIDEO
vI
v1
76h 49h
76h 31h
INPUT S-VIDEO
vI
v2
76h 49h
76h 32h
POWER ON/OFF IMPOSSIBLE
vPK
0
76h 50h 4Bh
30h
POWER ON/OFF POSSIBLE
vPK
1
76h 50h 4Bh
31h
NO SIGNAL SUPPLIED
vSM
0
76h 53h 4Dh
30h
SIGNAL SUPPLIED
vSM
1
76h 53h 4Dh
31h
Use the following commands to obtain the values of the items in the INFORMATION menu.
ITEM
Function
Data (Receive)
Character
ASCII
LAMP TIME (LOW)
vLE
76h 4Ch 45h
hhhhmm
RESOLUTION
vRESO
76h 52h 45h 53h 4Fh
HHHHxVVVV
VERTICAL FREQUENCY
vVFREQ
76h 56h 46h 52h 45h 51h
***.**
HORIZONTAL FREQUENCY
vHFREQ
76h 48h 46h 52h 45h 51h
***.**
SYNC. TYPE
vSYNCT
76h 53h 59h 4Eh 43h 54h
0 (NO SIGNAL), 3 (3wire), 4 (4wire),
5 (5wire), 6 (SCART)
“hhhh” and “mm” represent hours and minutes respectively.
“HHHH” and “VVVV” represent the horizontal and vertical resolutions respectively.
Use the following commands to obtain other information.
ITEM
Function
Data (Receive)
Character
ASCII
Model name
vMDL
76h 4Dh 44h 4Ch
****************(within 16 characters)
Serial number
vS/N
76h 53h 2Fh 4Eh
*******(within 7 characters)
Input source
vSOUCE
76h 53h 4Fh 55h 43h 45h
r1 r2 d1 v1 v2
Summary of Contents for LC62 CHASSIS XL6500LU
Page 22: ... 4 PCB LOCATION Fig 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ...
Page 108: ... MEMO ...
Page 119: ...P XL 00LU XL 00U ...
Page 123: ...P XL 00LU XL 00U ...
Page 130: ...P 12 XL 00LU XL 00U ...