DIAGNOSIS INFORMATION
Outline of self-diagnosis function
This projector is provided with the self-diagnosis function. In case of any failure, the LED at the top of the projector will indicate
the failure. There are two ways for diagnosis.
1. Connect a personal computer to the projector. Then, input [00~CHK] from the hyper-terminal window of the personal com-
puter during stand-by.
2. Connect a personal computer and click the “diagnosis” button of PCGC, the diagnostic software to read the warning history.
Note: Diagnosis can be also carried out by turning on the main power and then turning on the power of the operation panel.
However, as the diagnosis items are different and it may cause a secondary failure, carry out the diagnosis in either of
the above-mentioned ways in most cases.
Diagnosis result indication
LED indication and failures are described in the following table. LED can be reset “automatically” or “by turning on/off of the
main power” after the failure is corrected.
LED Error Indication List
--- : LED off
Orange : Both Red and Green light
Preferen-
tial order
LED Indication
Symptom
Failure
Check Point
Reset
POWER
STATUS
PCB
Reference
1
---
---
STBY5 is not
supplied.
AC system (Primary power source)
failure
INLET
F9F1
Unplug and plug
the power cord.
Secondary power source failure
POWER
SD connector 3pin
(STBY5) , Z972
Unplug and plug
the power cord.
STBY5 is
supplied
LED failure
MAIN
D7R0
Unplug and plug
the power cord.
2
Red / green
alternately
---
No power-on
Lamp cover open
MAIN
SL connector
LAMP COVER
Auto
Filter cover open
MAIN
SL connector
Filter cover
Auto
3
Red / green
alternately
red
flash
No power-on
Cooling fan (exhaust) stopped
MAIN
SX connector
Unplug and plug
the power cord.
red
flash 2
Cooling fan (lamp) stopped
POWER
SUB
NR connector
Unplug and plug
the power cord.
red
flash 3
Cooling fan (power) stopped
POWER
SUB
NA connector
Unplug and plug
the power cord.
red
flash 4
Cooling fan (PBS) stopped
POWER
SUB
NB connector
Unplug and plug
the power cord.
red
flash 5
Cooling fan (intake) stopped
POWER
SUB
NK connector
Unplug and plug
the power cord.
red
flash 6
Cooling fan (drive) stopped
POWER
SUB
ND connector
Unplug and plug
the power cord.
4
Red / green
alternately
Green
No power-on
I
2
C bus failure of E
2
PROM
MAIN
IC445, SCL0, SDA0
Unplug and plug
the power cord
Green
flash
I
2
C bus failure of GPIOO
MAIN
IC754, SCL0, SDA0
Unplug and plug
the power cord
Green
flash 6
I
2
C bus failure of WatchDog
MAIN
IC444, SCL0, SDA0
Unplug and plug
the power cord
5
Red / green
alternately
Orange
No power-on NR8R power failure
POWER,
MAIN
SD connector 2 pin
(NR8R)
Unplug and plug
the power cord
6
Red / green
alternately
Orange
flash
No power-on Disconnected thermister
MAIN
SZ connector
Unplug and plug
the power cord
7
Red
Red
No power-on
Power-on is prohibited because of
the end of the lamp life.
(2000 hours or more)
Replace the lamp and reset the lamp
operating time. (Press and hold the
Power, ,
and buttons on the pro-
jector together for 3 seconds.)
Manual
Summary of Contents for LC62 CHASSIS XL6500LU
Page 22: ... 4 PCB LOCATION Fig 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ...
Page 108: ... MEMO ...
Page 119: ...P XL 00LU XL 00U ...
Page 123: ...P XL 00LU XL 00U ...
Page 130: ...P 12 XL 00LU XL 00U ...