background image

 

 

 
 
 
 

Installation and operation manual 

KSGD02 Revision: 1.4 

Page 6 of 16 

R

KSGD-01WS-B 

!

Before installation 

 
  
Caution: 

 

 

Do not install the unit where combustible gas may leak.  
If the gas leaks and accumulates around the unit, an explosion may result.  

 

 

Ground the unit.  
Do  not  connect  the  ground  wire  to  gas  or  water  pipes,  lightning  rods,  or  telephone  ground  lines.  Improper 
grounding may result in electric shock.  

 

 

Install  the power cable so that  tension is not applied to the cable. Tension may cause  the cable to break  and 
generate heat which may, in turn, cause fire.  
 

 

Install a leak circuit breaker, as required.  
If a leak circuit breaker is not installed, electric shock may result.  

 

 

Use power line cables of sufficient current carrying capacity and rating.  
Cables that are too small may leak, generate heat, and cause a fire.  

 

 

Use only a circuit breaker and fuse of the specified capacity.  
A fuse or circuit breaker of a larger capacity or a steel or copper wire may result in a general unit failure or fire.  

 

 

Be very careful regarding product transportation.  
Two people should be used to carry products of 20kg or more.  

 

 

Some products use PP bands for packaging. Do not use any PP bands for a means of transportation.  

 

 

Safely dispose of the packing materials.  
Packing materials, such as nails and other metal or wooden parts, may cause stabs or other injuries.  
Tear apart and throw away plastic packaging bags so that children will not play with them - If children play with a 
plastic bag which has not been torn apart, they face the risk of suffocation.  

 
Before starting a test run 

 
  
Caution: 

 
 

 

Do not touch the switches with wet fingers.  
Touching a switch with wet fingers can cause electric shock.  

 

 

Do not touch the refrigerant pipes during and immediately after operation.  
During and immediately after operation, the refrigerant pipes may be hot or cold, depending on the condition of 
the refrigerant flowing through the refrigerant piping, compressor, and other refrigerant cycle parts. Your hands 
may suffer burns or frostbite if you touch the refrigerant pipes.  

 

 

Do not operate the air conditioner with the panels and guards removed.  
Rotating, hot, or high-voltage parts can cause injuries.  

 

 

Do not turn off the power immediately after stopping operation.  
Always wait at least five minutes before turning off the power. Otherwise, water leakage and other problems may 
occur. 

 
Disclaimer 
 
Warranty:  
All products manufactured on behalf of Mitsubishi Electric UK are warranted against defective materials for a period of three 
years from the date of delivery to the original purchaser. 

 

 

Warning: 

 
Mitsubishi Electric UK assumes no liability for damages consequent to the user of this product. We reserve the right to change 
this manual at any time without notice. The information furnished by us is believed to be accurate and reliable. However, no 
responsibility is assumed by us for its use, nor for any infringements of patents or other rights of third parties resulting from 
its use. 

 

 

!

!

Summary of Contents for k-con KSGD-01WS-B

Page 1: ...Installation and operation manual KSGD02 Revision 1 4 Page 1 of 16 R KSGD 01WS B Refrigerant leak detector Installation and operation manual Version 1 4 Manufactured for MITSUBISHI ELECTRIC UK ...

Page 2: ...In no event will the manufacturer be liable for any direct indirect special incidental or consequential damages resulting from any defect or omission in this manual even if advised of the possibility of such damages In the interest of continued product development the manufacturer reserves the right to make improvements to this manual and the products described herein at any time without notice or...

Page 3: ...erview 7 1 1 Specification Overview 7 2 Installation 8 2 1 Locating the sensor 8 2 2 Electrical connections 9 2 3 Other features 10 3 Operation 11 3 1 Operational matrix 11 4 Testing 12 4 1 Measuring the Gv 12 4 1 Bump test procedure 12 4 2 Full Operational test procedure 13 5 Fault finding 14 Revisions 15 Notes 16 ...

Page 4: ...namely boiler suit and safety glasses Improper handling may result in injury If refrigerant gas leaks during installation work ventilate the room If the refrigerant gas comes into contact with a flame poisonous gases will be released Install the controller according to this Installation Manual If the unit is installed improperly electric shock or fire may result Have all electric work done by a li...

Page 5: ... flares and flange connections The refrigerator oil will degrade if it is mixed with a large amount of mineral oil Use liquid refrigerant to fill the system If gas refrigerant is used to seal the system the composition of the refrigerant in the cylinder will change and performance may drop Do not use a refrigerant other than what is specified If the incorrect refrigerant R22 etc is used the chlori...

Page 6: ... packaging bags so that children will not play with them If children play with a plastic bag which has not been torn apart they face the risk of suffocation Before starting a test run Caution Do not touch the switches with wet fingers Touching a switch with wet fingers can cause electric shock Do not touch the refrigerant pipes during and immediately after operation During and immediately after op...

Page 7: ...ntinued product development the manufacturer reserves the right to make improvements to products with notice or obligation Housing White plastic OR Stainless steel fascia back box dry lining box supplied on request other options available Power 12 24V AC or DC Power usage Max 2 5VA 1VA nominal Relays 1 or 2 Contact rating 0 5A 125VAC 1A 24VDC Indicators 1 x Tri colour LED Sounder 85dB 2300Hz 300Hz...

Page 8: ... conditioning unit 2 Accessible for maintenance The KSGD should be mounted in a position where it can be easily accessed for maintenance and repairs 3 Minimize possibility of damage Mount the sensor in a position that minimizes the risk of mechanical damage to the unit 4 Minimize false alarms Semi conductor sensors can be poisoned exposure may take considerable time to recover Solvent paints and s...

Page 9: ...AC or DC 2 Power V2 3 Relay 1 NO1 Normally Open 4 Relay 1 C1 Common 5 Relay 2 NC2 Normally Closed 6 Relay 2 C2 Common Single relay version See section 3 for details on the relay operation and functions Relay s are energized in normal operation the relay will de energize if an alarm or fault occurs or if power is not present The tables above show the relay s in the de energized power removed state ...

Page 10: ... as the sensor and buzzer enable link are located on the front of the detector PCB When the buzzer enable disable link is fitted the buzzer will operate when required Remove this link to disable the buzzer permanently i Status LED Buzzer Buzzer Enable Disable link Sensor Factory use only Fig 2 4 KSGD other features ...

Page 11: ...EN Normal operation 3 4 5 6 3 4 4 5 Constant GREEN OFF 0 4 1VDC CLOSED OPEN CLOSED OPEN Sensor fault 3 4 5 6 3 4 4 5 RED OFF 1Hz 1 x AMBER FLASH PER MINUTE Pulses once per minute 0 1VDC OPEN CLOSED OPEN CLOSED As the gas concentration increases Pre alarm Level 1 Reading 500ppm For 2 seconds 3 4 5 6 3 4 4 5 Flashing GREEN OFF 2Hz OFF 2 5VDC CLOSED OPEN CLOSED OPEN Pre alarm Level 2 Reading 1000ppm ...

Page 12: ...ntaminant and the voltage should subside Operating State Dual Relay version Connection terminal states Single Relay version Connection terminal states LED Buzzer Gv Voltage Normal operation 3 4 5 6 3 4 4 5 Constant GREEN OFF 0 4 1VDC CLOSED OPEN CLOSED OPEN 2 Using a small amount of butane or equivalent spray gas at the sensor for approximately 30 to 40 seconds 3 The sensor will enter the High Lev...

Page 13: ...1 to 2 minutes Operating State Dual Relay version Connection terminal states Single Relay version Connection terminal states LED Buzzer Gv Voltage Normal operation 3 4 5 6 3 4 4 5 Constant GREEN OFF 0 4 1VDC CLOSED OPEN CLOSED OPEN 3 Place the plastic tube directly over the perforation on the cover plate and turn the regulator valve fully anticlockwise to release the test gas Apply test gas onto t...

Page 14: ...ypically less than 5 minutes It is recommended that the sensor is not subjected to test gas for a prolonged period 3 minutes as recovery may become significantly longer Please ensure the regulator is switched off after use and the bottle is stored in a ventilated space See section 3 1 for supplementary information of Gv voltages at different operational states The detectors relays are normally ene...

Page 15: ...Installation and operation manual KSGD02 Revision 1 4 Page 15 of 16 R KSGD 01WS B Revisions 1 4 11 12 2019 First released version KR ...

Page 16: ...Installation and operation manual KSGD02 Revision 1 4 Page 16 of 16 R KSGD 01WS B Notes ...

Reviews: