For Maximum Safety
• Mitsubishi inverters are not designed or manufactured to be used in equipment or systems in situations that
can affect or endanger human life.
• When considering this product for operation in special applications such as machinery or systems used in
passenger transportation, medical, aerospace, atomic power, electric power, or submarine repeating
applications, please contact your nearest Mitsubishi sales representative.
• Although this product was manufactured under conditions of strict quality control, you are strongly advised
to install safety devices to prevent serious accidents when it is used in facilities where breakdowns of the
product are likely to cause a serious accident.
• Please do not use this product for loads other than three-phase induction motors.
Print Date
*
Manual Number
Revision
Sep. 2004
IB(NA)-0600218ENG-A First edition
Dec. 2004
IB(NA)-0600218ENG-B
⋅
FR-F720 - 03160 to 04750 - NA
⋅
FR-F740 - 04320 to 12120 - NA
May 2006
IB(NA)-0600218ENG-C
⋅
Electronic thermal relay function operation characteristic.
⋅
Pr. 539 Modbus-RTU communication check time interval
⋅
Voltage/current input switch
Nov. 2007
IB(NA)-0600218ENG-D
⋅
Breaker selection when using the inverter as UL or cUL listed product
⋅
Setting values "10, 11" of Pr.495 Remote output selection
Sep. 2009
IB(NA)-0600218ENG-E
・
Pr. 59
Remote function selection
setting value "11 ", "12 ", "13 "
・
Pr. 29
Acceleration/deceleration pattern selection
setting value "6"
・
Pr. 30
Regenerative function selection
setting value "10", "11", "20", "21"
・
Pr.128
PID action selection
setting value "110", "111", "120", "121"
・
Pr.167
Output current detection operation selection
setting value "10", "11"
・
Pr.178 to Pr.189 Input terminal function selection
setting value "70", "71", "72"
・
Pr.190 to Pr.196 Output terminal function selection
setting value "48", "79", "85",
"148", "179", "185"
・
Pr. 261
Power failure stop selection
setting value "21", "22"
・
Pr.522 Output stop frequency
・
Pr.653 Speed smoothing control
,
Pr.654 Speed smoothing cutoff frequency
・
Pr.553 PID deviation limit
,
Pr.554 PID signal operation selection
,
C42 (Pr.934) PID
display bias coefficient
,
C43 (Pr.934) PID display bias analog value
,
C44 (Pr.935) PID
display gain coefficient
,
C45 (Pr.935) PID display gain analog value
・
Pr.799 Pulse increment setting for output power
・
Pr.153
Zero current detection time
setting range "0 to 10s"
・
Appendix 1 Instructions for compliance with the EU Directives
Additions
Additions
Additions
Additions
Partial changes