58
CC-Link I/O specifications
2.3.2
I/O signal when CC-Link Ver.2 double setting is selected
(Pr. 544 = 112)
The device points usable in CC-Link communication are 32 input (RX) points (12
points are available for PLC function), 32 output (RY) points (12 points are available
for PLC function), 4 remote register (RWr) points and 4 remote register (RWw) points.
(1) Remote I/O
PLC
Function
Device
No.
Remote
Output
Device
No.
Signal
PLC
Function
Device
No.
Remote
Input
Device
No.
Signal
X30
RYn0
Forward rotation command
Y30
RXn0
Forward running
X31
RYn1
Reverse rotation command
Y31
RXn1
Reverse running
X32
RYn2
High-speed operation
command
(terminal RH function) *1
Y32
RXn2
Running
(terminal RUN function) *2
X33
RYn3
Middle-speed operation
command
(terminal RM function) *1
Y33
RXn3
Up to frequency
(terminal SU function) *2
X34
RYn4
Low-speed operation
command
(terminal RL function) *1
Y34
RXn4
Overload alarm
(terminal OL function) *2
X35
RYn5
Jog operation command
(terminal JOG function) *1
Y35
RXn5
Instantaneous power failure
(terminal IPF function) *2
X36
RYn6
Second function selection
(terminal RT function) *1
Y36
RXn6
Frequency detection
(terminal FU function) *2
X37
RYn7
Current input selection
(terminal AU function) *1
Y37
RXn7
Error
(terminal ABC1 function) *2
X38
RYn8
Selection of automatic restart after
instantaneous power failure
(terminal CS function) *1
Y38
RXn8
⎯
(terminal ABC2 function)
*2
X39
RYn9
Output stop
Y39
RXn9
Pr. 313
assignment function
(DO0)
X3A
RYnA
Start self-holding selection
(terminal STOP function) *1
Y3A
RXnA
Pr. 314
assignment function
(DO1)
X3B
RYnB
Reset
(terminal RES function) *1
Y3B
RXnB
Pr. 315
assignment function
(DO2)
⎯
RYnC
Monitor command
⎯
RXnC
Monitoring
⎯
RYnD
Frequency setting command
(RAM)
⎯
RXnD
Frequency setting completion
(RAM)
⎯
RYnE
Frequency setting command
(RAM, EEPROM)
⎯
RXnE
Frequency setting completion
(RAM, EEPROM)
⎯
RYnF
Instruction code execution
request
⎯
RXnF
Instruction code execution
completion
⎯
RY(n+1)0
to
RY(n+1)7
Reserved
⎯
RX(n+1)0
to
RX(n+1)7
Reserved
⎯
RY(n+1)8
Not used
(initial data process
completion flag)
⎯
RX(n+1)8
Not used
(initial data process request
flag)
⎯
RY(n+1)9
Not used
(initial data process request
flag)
⎯
RX(n+1)9
Not used
(initial data process
completion flag)
⎯
RY(n+1)A
Error reset request flag
⎯
RX(n+1)A
Error status flag
⎯
RY(n+1)B
to
RY(n+1)F
Reserved
⎯
RX(n+1)B
Remote station ready
RX(n+1)C
to
RX(n+1)F
Reserved
Summary of Contents for FR - F700
Page 1: ...INVERTER FR F700 FR F 700 INVERTER PLC FUNCTION PROGRAMMING MANUAL ...
Page 7: ...VI MEMO ...
Page 131: ...124 Sequence instructions Program Examples LD LDI AND ANI OR ORI ORB ANB Coding Coding Coding ...
Page 207: ...200 MEMO ...
Page 211: ...204 MEMO ...
Page 212: ...205 APPENDIX Appendix 1 Instruction processing time 206 ...
Page 216: ...FR F 700 INVERTER ...