203
How to read the error code
4
ERRO
R CODE L
IST
“OPERATION
ERROR”
[Checked at
instruction
execution]
50
Run
(Stop)
(1) Divided by zero
(2) When using the PR
command
•
A value other than "01
to 03" is set in the lower
8 bits of
+0.
•
A value out of the setting
range is set in the upper
8 bits of
+0.
•
Monitors, faults, and
parameters are set
exceeding the number
of selectable items.
(1) Read the error step by
use of peripheral
device, and check and
correct the program at
that step.
(2)
•
Set a value from "01
to 03" in the lower 8
bits of
+0.
•
Check the upper 8
bits of
+0.
•
Set monitors, faults,
parameters within the
number of selectable
items.
Error Name
Error
Code
(D9008)
Status
Definition and Cause
Corrective Action
S
S
S
S
Summary of Contents for FR - F700
Page 1: ...INVERTER FR F700 FR F 700 INVERTER PLC FUNCTION PROGRAMMING MANUAL ...
Page 7: ...VI MEMO ...
Page 131: ...124 Sequence instructions Program Examples LD LDI AND ANI OR ORI ORB ANB Coding Coding Coding ...
Page 207: ...200 MEMO ...
Page 211: ...204 MEMO ...
Page 212: ...205 APPENDIX Appendix 1 Instruction processing time 206 ...
Page 216: ...FR F 700 INVERTER ...