4.14.4 Overspeed detection (Pr.374)
The drive unit output can be shut off in case of overspeed.
Parameter
number
Name
Initial value
Setting range
Description
374
Overspeed detection level
3450r/min
0 to 4800r/min
When the motor speed reaches or
exceeds the speed set in
Pr.374
,
overspeed (E.OS) occurs, and the drive
unit outputs is stopped.
The above parameters can be set when
Pr.160 Extended function display selection
= "0".
When a value exceeding 3000 r/min is set, the rotation speed will be limited at 3000 r/min.
Also, when an S-PM geared motor is used, the maximum setting value differs depending on the drive unit capacity. (0.2 to 2.2K: 12000 r/min, 3.7K: 8000
r/min)
ALM
Motor rotation speed
Time
E.OS
Coast to stop
ON
Pr.374